━ Trouble Shooting for Alarm Code
Content
Causes and solutions
4
DC Motor Up Time Out
[Causes]
The motor is not functional or the block plate of the sensor is at wrong
position.
[Solutions]
(1) Check whether the motor is functional.
(2) Check whether the cable dropped off.
(3) Adjust the position of the block plate of the sensor.
5
DC Motor Down Time Out
[Causes]
The motor is not functional or the block plate of the sensor is at wrong
position.
[Solutions]
(1) Check whether the motor is functional.
(2) Check whether the cable has dropped off.
(3) Adjust the position of the block plate of the sensor.
6
Y_SoftLimt+
[Causes]
Manual Y JOG+ operation exceeds the distance of the software.
[Solutions]
(1) Alarm Reset
(2) Manual Y JOG- operation.
7
Y_SoftLimt-
[Causes]
Manual Y JOG- operation exceeds the distance of the software.
[Solutions]
(1) Alarm Reset
(2) Manual Y JOG- operation.