Carrier A Series Installation, Start-Up, Operating And Service And Maintenance Instructions page 34

Variable-speed, ecm induced-combustion, 2-stage 4-way multipoise, non-condensing gas furnace
Table of Contents

Advertisement

PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions
CAUTION
!
FURNACE OVERHEATING HAZARD
Failure to follow this caution may result in reduced furnace life.
Recheck temperature rise. It must be within limits specified on the
rating plate. Recommended operation is at the mid-point of rise range
or slightly above.
l. Proceed to Step 6, "Set Blower Off Delay" before installing
blower access door.
7. Set Blower Off Delay. (See
a. Remove blower access door if installed.
b. Turn Dip switch SW-7 or SW-8 ON or OFF for desired blower
off delay. (See
Fig.
36,
Fig. 54
Table 10 – Blower Off Delay Setup Switch
DESIRED HEATING MODE
BLOWER OFF DELAY (SEC.)
90
120
150
180
8. Set thermostat heat anticipator.
a. Mechanical thermostat. Set thermostat heat anticipator to match
the amp. draw of the electrical components in the R-W/W1
circuit. Accurate amp. draw readings can be obtained at the wires
normally connected to thermostat subbase terminals, R and W.
The thermostat anticipator should NOT be in the circuit while
measuring current.
(1.) Set SW1-2 switch on furnace control board to ON.
(2.) Remove thermostat from subbase or from wall.
(3.) Connect an amp. meter across the R and W subbase
terminals or R and W wires at wall. (See
10 TURNS
5.0 AMPS ON AMMETER
EXAMPLE:
10 TURNS AROUND JAWS
Fig. 52 – Amp. Draw Check with Ammeter
(4.) Record amp. draw across terminals when furnace is in low
heat and after blower starts.
(5.) Set heat anticipator on thermostat per thermostat
instructions and install on subbase or wall.
(6.) Turn SW1-2 switch OFF.
(7.) Install blower access door.
b. Electronic thermostat: Set cycle rate for 3 cycles per hr.
9. Set Airflow for Air Conditioning -Single Stage and High Stage
Cooling.
The ECM blower can be adjusted for a range of airflow for Low
Speed or High Speed cooling. See
(With Filter).
The cooling airflow is adjusted by turning Setup switches SW2-6,
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table
10.)
and
Fig.
59).
SETUP SWITCH
(SW-7 AND -8)
POSITION
SW1-7
SW1-8
OFF
OFF
ON
OFF
OFF
ON
Fig.
52.
THERMOSTAT SUBBASE
TERMINALS WITH
THERMOSTAT REMOVED
(ANITICIPATOR, CLOCK, ETC.,
MUST BE OUT OF CIRCUIT.)
HOOK-AROUND
AMMETER
R Y W G
FROM UNIT 24-V
CONTROL TERMINALS
0.5 AMPS FOR THERMOSTAT
=
ANTICIPATOR SETTING
Table
4-Air Delivery - CFM
SW2-7 and SW2-8 either ON or OFF. Select the required airflow.
(See
Fig.
55).
NOTE: 5.5 ton airflow will truncate at 2200 cfm on applicable models.
For a complete explanation of cooling airflow, refer to the section titled
"Sequence of Operation."
10. The Continuous Fan airflow selection via Setup switches SW2-3,
SW2-4, SW2-5 is also the switch setting for low-speed cooling
when the furnace is used with a two-speed cooling or heat pump
unit. Refer to the Adjustments section (also
setup switch configurations. This setup feature allows continuous
fan airflow or low-cooling airflow to be adjusted.
The continuous fan speed can be further adjusted at the thermostat
using the Continuous Blower Speed Selection from Thermostat
function. Changing the continuous fan speed at the thermostat
DOES NOT change the low speed cooling airflow selected at the
control board. See the section titled Continuous Blower Speed
Selection from Thermostat in the Sequence of Operation section of
this document.
SECONDS G
FOR 1
REVOLUTION
10
ON
11
ON
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
A96316
38
39
40
41
42
43
44
45
46
47
48
49
34
Table 11 – Gas Rate (CU ft./hr)
SIZE OF TEST DIAL
SECONDS
FOR 1
1 Cu
2 Cu
5 Cu
REVOLUTION
Ft.
Ft.
Ft.
360
720
1800
50
327
655
1636
51
300
600
1500
52
277
555
1385
53
257
514
1286
54
240
480
1200
55
225
450
1125
56
212
424
1059
57
200
400
1000
58
189
379
947
59
180
360
900
60
171
343
857
62
164
327
818
64
157
313
783
66
150
300
750
68
144
288
720
70
138
277
692
72
133
267
667
74
129
257
643
76
124
248
621
78
120
240
600
80
116
232
581
82
113
225
563
84
109
218
545
86
106
212
529
88
103
206
514
90
100
200
500
92
97
195
486
94
95
189
474
96
92
185
462
98
90
180
450
100
88
176
439
102
86
172
429
104
84
167
419
106
82
164
409
108
80
160
400
110
78
157
391
112
76
153
383
116
75
150
375
120
73
147
367
Fig. 54
and
Fig.
55) for
SIZE OF TEST DIAL
1 Cu
2 Cu
5 Cu
Ft.
Ft.
Ft.
72
144
360
71
141
355
69
138
346
68
136
340
67
133
333
65
131
327
64
129
321
63
126
316
62
124
310
61
122
305
60
120
300
58
116
290
56
112
281
54
109
273
53
106
265
51
103
257
50
100
250
48
97
243
47
95
237
46
92
231
45
90
225
44
88
220
43
86
214
42
84
209
41
82
205
40
80
200
39
78
196
38
76
192
38
75
188
37
74
184
36
72
180
35
71
178
35
69
173
34
68
170
33
67
167
33
65
164
32
64
161
31
62
155
30
60
150