Carrier A Series Installation, Start-Up, Operating And Service And Maintenance Instructions page 17

Variable-speed, ecm induced-combustion, 2-stage 4-way multipoise, non-condensing gas furnace
Table of Contents

Advertisement

PG80VTLA: Installation, Start-up, Operating and Service and Maintenance Instructions
Unit Size:
Clg/CF Switch settings
66135D
Clg
SW2-8
SW2-7
Switches:
Clg Default:
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
Cooling
(SW2-8,7,6)
ON
OFF
ON
ON
ON
ON
Maximum Clg Airflow
CF Switches
SW2-5
SW2-4
Low-Clg
OFF
OFF
Default:
OFF
OFF
OFF
ON
OFF
ON
Low-Cooling
ON
OFF
(SW2-5,4,3)
ON
OFF
ON
ON
ON
ON
Cont. Fan
OFF
OFF
Default:
OFF
OFF
OFF
ON
OFF
ON
Continuous
Fan
ON
OFF
(SW2-5,4,3)
ON
OFF
ON
ON
ON
ON
High Heat Airflow
Heating
(SW1)
Low Heat Airflow
1.Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW2-2 set to OFF.
Set both SW1-5 and SW2-2 to ON for +7% airflow (nominal 370 CFM/ton).
Set SW1-5 to ON and SW2-2 to OFF for +15% airflow (nominal 400 CFM/ton).
Set SW2-2 to ON and SW1-5 to OFF for -7% airflow (nominal 325 CFM/ton).
The above adjustments in airflow are subject to motor horsepower range/capacity.
This applies to Cooling and Low-Cooling airflow, but does not affect continuous fan airflow.
2.Maximum cooling airflow is achieved when switches SW2-6, SW2-7, SW2-8 and SW1-5 are set to ON, and SW2-2 is set to OFF.
3.All heating CFM's are when comfort/efficiency adjustment switch (SW1-4) is set to OFF
4.Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not recommended because high-heat operation will be
above 1.0 ESP.
5.All airflows on 21" casing size furnaces are 5% less on side return only installations.
6.Side returns for 24.5" casing sizes require two sides, or side and bottom, to allow sufficient airflow at the return of the furnace.
7.Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return or excessive watt draw may result. A minimum filter size of 20 x 25"(508 x 635 mm) is required.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 4 – Air Delivery - CFM (With Filter)* (Continued)
4
COOLING
AND HEATING AIR DELIVERY - CFM (Bottom Return
(SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.)
SW2-6
0.1
0.2
OFF
2105
2050
ON
990
885
OFF
1180
1090
ON
1355
1270
OFF
1535
1465
ON
1735
1670
OFF
2105
2050
ON
2280
2225
2
2360
2310
SW2-3
OFF
990
885
ON
800
670
OFF
990
885
ON
1180
1090
OFF
1355
1270
ON
1535
1465
OFF
1735
1670
ON
2105
2050
OFF
740
605
ON
740
605
OFF
900
775
ON
1080
980
OFF
1080
980
ON
1080
980
OFF
1080
980
ON
1080
980
3
2130
2075
3
1855
1795
External Static Pressure (ESP)
0.3
0.4
0.5
1995
1940
1880
780
665
570
995
900
815
1190
1105
1020
1395
1320
1245
1605
1535
1470
1995
1940
1880
2175
2120
2065
2265
2215
2160
780
665
570
540
410
280
780
665
570
995
900
815
1190
1105
1020
1395
1320
1245
1605
1535
1470
1995
1940
1880
470
360
255
470
360
255
650
525
400
885
785
680
885
785
680
885
785
680
885
785
680
885
785
680
2020
1970
1910
1730
1670
1605
17
5
With Filter)
0.6
0.7
0.8
1820
1765
1705
See Note 4
715
635
555
940
855
775
1165
1095
1025
1405
1335
1270
1820
1765
1705
2010
1955
1905
2115
2060
2010
See Note 4
See Note 4
See Note 4
715
635
555
940
855
775
1165
1095
1025
1405
1335
1270
1820
1765
1705
See Note 4
See Note 4
See Note 4
595
510
430
595
510
430
595
510
430
595
510
430
595
510
430
1855
1805
1745
1545
1480
1420
0.9
1.0
1650
1590
475
400
700
630
945
875
1205
1140
1650
1590
1850
1800
1960
1870
475
400
700
630
945
875
1205
1140
1650
1590
345
260
345
260
345
260
345
260
345
260
1690
1630
1360
1300