Before Each Use - Roughneck 58267 Owner's Manual

Heavy-duty air-operated oil pump
Table of Contents

Advertisement

FIG.2: Grounding guide
Installation
Standard installation
1: Cut-off valve
2: Filter
3: Regulator
4: Lubricator
5: Control valve
6: Locking adapter
7: Hose reel
The above installation is part of the oil supply system. If you need installation for the whole air circle
transfer, contact the manufacturer or distributor.
Note: To avoid damage, do not hang any device at the air inlet.
Place the pump into lock adapter (Fig 3, Part 6).
Install to the trolley.
Install cut-off valve (Fig 3, Part 1).
Install filter (Fig 3, Part 2).
Install regulator which controls the speed and adjusts the air pressure (Fig 3, Part 3).
Install lubricator which self-lubricates (Fig 3, Part 4).
Install control valve which controls flux. When the speed is too fast, pump will automatically
self-close to avoid pump be damaged (Fig 3, Part 5).
Connect to oil output.
Inspect before each use; check that all connections are tight and secure.
Never use if parts are damaged or broken; replace damaged or broken parts before operating.
Disconnect air hose and relieve air pressure before servicing.
Page 9 of 17
Fig.3: Oil supply system installation