Honda CRF1000A Owner's Manual page 150

Hide thumbs Also See for CRF1000A:
Table of Contents

Advertisement

Electrical Trouble
ABS Main Fuse & DCT Main Fuse
CRF1000D
Fuse box
covers
ABS main fuse
DCT main fuse
146
u
Blown Fuse
ABS main fuse and DCT
main fuse box suspension
1. Remove the battery box cover.
2. Pull the ABS main fuse and DCT main fuse
box suspension out.
3. Open the fuse box covers.
4. Pull the ABS main fuses and DCT main
fuse out one by one with the fuse puller in
the tool kit and check for a blown fuse.
Always replace a blown fuse with a spare
fuse of the same rating.
u
Spare main fuse is provided in the
starter magnetic switch.
5. Reinstall parts in the reverse order of
removal.
NOTICE
If a fuse fails repeatedly, you likely have an electrical
problem. Have your motorcycle inspected by your dealer.