4-2-7. Hold

Current value output data latch (latching)
In the current value mode, this function holds output data and Go/
No GO judgment output for that value.
[Latch conditions]
. The start input signal is set as the hold input by the parameter
setting.
. Current value mode
n
This function does not operate when the measuring mode is peak
value mode.
Latch ON
16
(E)
Latch OFF
Current value
Peak value data update stop (pause)
This function enables the following measurements to be performed
while the peak values are held.
It is useful when measuring the peak values for a multiple number
of workpieces or for a multiple number of locations.
When the peak value data update stop function is set
to ON
The peak value updating is stopped. The current value is constantly
updated.
If the maximum value mode, minimum value mode or peak-to-
peak value mode is set as the measuring mode, the Go/No GO
judgment output and the output data are not updated even when the
measuring unit is operated.
When the peak value data update stop function is set
to OFF
The peak values are constantly updated.
Pause ON Pause OFF
Maximum value
Current value
MG10-P1 / MG10-P2