In units with R404A and POE oil, the use of inert gas brazing procedures is mandatory, other-
wise compressor failure will occur. See Technical Procedure 98-50553-00 Inert Gas Brazing for
more information.
Use only ethylene glycol antifreeze (with inhibitors) in system as glycol by itself will damage
the cooling system. Always add pre-mixed 50/50 antifreeze and water to radiator/engine. Never
exceed more than a 50 percent concentration of antifreeze. Use a low silicate antifreeze.
When changing oil filters, the new filters should be primed with clean oil. If the filters are not
primed, the engine may operate for a period with no oil supplied to the bearings.
When changing fuel filter, the new filter should be filled with clean fuel.
Extreme care must be taken to ensure the manifold common connection remains immersed in
oil at all times. Otherwise air and moisture will be drawn into the compressor.
Check for correct power connection with connectors located in Main Control Relay Box.
Be certain that the unit is connected to an appropriate power source.
Do not allow the insulated jumper wire used to change unit Configurations to touch any
ground.
NEVER POUR COLD WATER INTO A HOT ENGINE. However, hot water can always be added to
a cold engine.