Mitsubishi Diamondview DV75UM User Manual page 53

Table of Contents

Advertisement

Other Control
 Adjust up to monitor [CMD: RCU]
[Transmit] : PC → 07 01 02 52 43 55 02 08 → Monitor
[Return] : Monitor → 07 01 00 52 43 55 02 08 → PC
 Reset all to monitor [CMD: ALL]
[Transmit] : PC → 07 01 02 41 4C 4C 00 08 → Monitor
[Return] : Monitor → 07 01 00 41 4C 4C00 08 → PC
 Read serial number monitor [CMD: SER]
[Transmit] : PC → 07 01 01 53 45 52 08 → Monitor
[Return] : Monitor → 07 01 00 53 45 52 S(0) ... S(12) 08 → PC , S(0) ~ S(12): serial number in ASCII
 Read firmware version monitor [CMD: GVE]
[Transmit] : PC → 07 01 01 47 56 45 08 → Monitor
[Return] : Monitor → 07 01 00 47 56 45 S(0) ... S(5) 08 → PC , S(0) ~ S(5): firmware version in ASCII
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents