Main Item Control Item CMD Type
Examples
Power Control and Input Source
 Turn monitor power off [CMD: POW]
[Transmit] : PC → 07 01 02 50 4F 57 00 08 → Monitor
[Return] : Monitor → 07 01 00 50 4F 57 00 08 → PC
 Turn monitor power on [CMD: POW]
[Transmit] : PC → 07 01 02 50 4F 57 01 08 → Monitor
[Return] : Monitor → 07 01 00 50 4F 57 01 08 → PC
 Read Power Status from monitor [CMD: POW]
[Transmit] : PC → 07 01 01 50 4F 57 08 → Monitor
[Return] : Monitor → 07 01 00 50 4F 57 XX 08 → PC
XX = 0, the set is off. XX = 1, the set is on.
Display Adjustment
 Read back light from monitor [CMD: BRI] (If the setting of back light is 80)
[Transmit] : PC → 07 0101 42 52 49 08 → Monitor
[Return] : Monitor → 07 01 00 42 52 49 50 08 → PC
 Set back light 80 to monitor [CMD: BRI]
[Transmit] : PC → 07 01 02 42 52 49 50 08 → Monitor
[Return] : Monitor → 07 01 00 42 52 49 50 08 → PC
 Set Contrast 30 to monitor [CMD: CON]
[Transmit] : PC → 07 01 02 43 4F 4E 1E 08 → Monitor
[Return] : Monitor → 07 01 00 43 4F 4E 1E 08 → PC
 Read Contrast from monitor [CMD: CON] (If the monitor contrast setting is 50)
[Transmit] : PC → 07 0101 43 4F 4E 08 → Monitor
[Return] : Monitor → 07 01 00 43 4F 4E 32 08 → Monitor
Scaling Adjustment
 Set monitor to 4:3 [CMD: ASP]
[Transmit] : PC → 07 01 02 41 53 50 02 08 → Monitor
[Return] : Monitor → 07 01 00 41 53 50 02 08 → PC
Value
(HEX)
FD4
W/R
00~FF
SNS
W
00
Reply
Content
(HEX)
00~FF
DNS Address 4
00
Save Static IP Settings
CMD (HEX) Remark
46 44 34
53 4E 53
52