Wall Mounting (Optional); Wiring Requirements - Weidmuller IE-WL-AP-BR-CL-ABG-EU Hardware Installation Manual

Wireless access point / bridge / client
Table of Contents

Advertisement

Wall Mounting (optional)

For some applications, it may be more convenient to mount the
IE-WL-AP-BR-CL-ABG to a wall, as illustrated below.
STEP 1:
Remove the aluminum
DIN-Rail attachment plate
from the
IE-WL-AP-BR-CL-ABG, and
then attach the wall mount
plates with M3 screws, as
shown in the adjacent
diagrams.
STEP 2:
Mounting the IE-WL-AP-BR-CL-ABG to a wall requires
4 screws. Use the IE-WL-AP-BR-CL-ABG device, with
wall mount plates attached, as a guide to mark the
correct locations of the 4 screws. The heads of the
screws should be less than 6.0 mm in diameter, and
the shafts should be less than 3.5 mm in diameter, as
shown in the figure at the right.
Do not screw the screws in all the way—leave a space
of about 2 mm to allow room for sliding the wall mount
panel between the wall and the screws.
NOTE Test the screw head and shank size by inserting the screw into
one of the keyhole shaped apertures of the Wall Mounting Plates
before it is screwed into the wall.
STEP 3:
Once the screws are fixed
into the wall, insert the four
screw heads through the
large opening of the
keyhole-shaped apertures,
and then slide the
IE-WL-AP-BR-CL-ABG
downwards, as indicated to
the right. Tighten the four
screws for added stability.

Wiring Requirements

WARNING
Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your Weidmüller wireless device.
6.0 mm
3.5 mm
- 6 -
top
plate
bottom
plate

Advertisement

Table of Contents
loading

Table of Contents