Atex Information - Weidmuller IE-WL-AP-BR-CL-ABG-EU Hardware Installation Manual

Wireless access point / bridge / client
Table of Contents

Advertisement

RS-232 Connection
The IE-WL-AP-BR-CL-ABG has one RS-232 (8-pin RJ45) console port
located on the front panel. Use either an RJ45-to-DB9 or RJ45-to-DB25
cable to connect the console port of the wireless device to your PC's COM
port. You may then use a console terminal program to access the
IE-WL-AP-BR-CL-ABG for console configuration.
Console Pinouts for 10-pin or 8-pin RJ45
10-Pin Description 8-Pin
1
-----
2
DSR
1
3
RTS
2
4
GND
3
5
TxD
4
6
RxD
5
7
DCD
6
8
CTS
7
9
DTR
8
10
-----
NOTE
1. The pin numbers for male DB9 and DB25 connectors, and
hole numbers for female DB9 and DB25 connectors are
labeled on the connector. However, the numbers are
typically quite small, so you may need to use a magnifying
glass to see the numbers clearly.
2. The pin numbers for both 8-pin and 10-pin RJ45 connectors
(and ports) are typically not labeled on the connector (or
port). Refer to the Pinout diagram above to see how RJ45
pins are numbered.

ATEX Information

II 3G
1. DEMKO certification number: 11 ATEX 1105896X
2. Ambient range (-40°C ≤ Tamb ≤ 75°C)
3. Certification string: Ex nA nL IIC T4
4. Standards covered ( EN60079-0:2006, EN60079-15:2005)
5. The conditions of safe usage:
a.
The Ethernet Communication Devices are intended for mounting
in an IP54 enclosure and used in an area of not more than
pollution degree 2 as defined by IEC60664-1.
b. Conductors suitable for use in an ambient temperature greater
than 93°C must be used for the Power Supply Terminal.
c.
A 4 mm2 conductor must be used when connection to the
external grounding screw is utilized.
d. Cables must be suitable for use in an ambient temperature
greater than 93°C.
1