E6 L
The failure code displayed will be "E-5 Sensor" when receiving the E5 Sen-
EVEL AND
sor error, enter diagnostic mode and check the error log. Below is a list of
B
C
LINK
ODES
status display codes. When the drive is faulted, the Status LED blinks out
the default code. The code will blink the proper number of times, pause
with the LED off, and then repeat the code.
STATUS CODE
No Blink (Steady On)
Fast (Steady Blink)
LED Off
1 Blink (E601)
2 Blink (E602)
3 Blink (E603)
4 Blink (E604)
5 Blink (E605)
6 Blink (E606)
7 Blink (E607)
8 Blink (E608)
Z 7 T r e a d m i l l O w n e r ' s G u i d e
E6 Level and Blink Codes
DESCRIPTION
No Faults
No Faults
AC Line Power
Insufficient
100% Command
Sensor Feedback Error
Voltage Trip Error
Output Over Current
Control Supply Under
Voltage
Drive Over Temperature
AC Over Voltage
Output Short Circuit
C
M
ARE AND
AINTENANCE
IMPLICATION
Running
Ready
No or Low Voltage
Runaway Command
Sensor Error
Motor Issue
High Motor Current
Inadequate Power Line
MCB Over Tempera-
ture
Line Voltage Too High
Short Circuit to Motor
63