Example 4: DESFire Frame Level Chaining (Native Mode)
In this example, the application has to do the "Frame Level Chaining".
To get the version of the DESFire card:
Step 1: Send an APDU {60h} to get the first frame. INS=60h
Answer: AF 04 01 01 00 02 18 05h [$1805h]
Step 2: Send an APDU {AFh} to get the second frame. INS=AFh
Answer: AF 04 01 01 00 06 18 05h [$1805h]
Step 3: Send an APDU {AFh} to get the last frame. INS=AFh
Answer: 00 04 52 5A 19 B2 1B 80 8E 36 54 4D 40 26 04h [$2604h]
Note: In DESFire Native Mode, the status code [90 00h] will not be added to the response if the
response length is greater than 1. If the response length is less than 2, the status code [90 00h] will
be added in order to meet the requirement of PC/SC. The minimum response length is 2.