  • Page 1 BASE SOFT LIGHT E SERIES USER MANUAL July 2019...
  • Page 3: Safety Information

    Safety Information 1. Do not open or disassemble the cover to reduce the risk of electric shock. 2. Please wear safety equipment such as safety helmet during work. WARNING 3. Be sure to fix the safety chain on the product when installing and moving. 4.
  • Page 4: Table Of Contents

    Contents Safety Information [Setting] [Error Information] Contents Temperature Sensor Mode Change [Fixture Information] Network Connection Channel Mode Change [Protocols] Fixture Information DMX512 Address Setup DMX Protocols Fixture Exterior View Brightness (Intensity) Adjust RDM Protocols Dimensions CCT Adjust (Correlated Color Temperature) Technical Specifications Fixture ID Setup and Change Photometric Diagram...
  • Page 5: Fixture Information

    Fixture Information E Series is a flat light source lighting fixture mainly used in broadcasting studios, and it is excellent in diffusivity, low in glare and not exposed to elements. The LED lighting source sets on the side(edge) with reflection and pattern optical technology applied.
  • Page 6: Fixture Exterior View

    Fixture Exterior View Fixed Knob Connector Panel Handle Smart Touch LCD Screen Stirrup - 6 -...
  • Page 7: Dimensions

    Dimensions (E1360) (inch) - 7 -...
  • Page 8 Dimensions (E2040) (inch) - 8 -...
  • Page 9 Dimensions (E2440) (inch) - 9 -...
  • Page 10 Dimensions (E3060) (inch) - 10 -...
  • Page 11: Technical Specifications

    Technical Specifications E1360 E2040 (E4) E2440 (E6) E3060 (E8) Physical Size 774 x 212 x 154mm 571 x 296 x 112mm 571 x 365 x 112mm 777 x 419 x 112mm Beam Angle 135° Weight (kg/lbs) 8.6 / 19 6.7 / 14.8 8.2 / 18.1 12 / 26.5 Handling...
  • Page 12: Photometric Diagram

    Photometric Diagram E1360 E2040 E2440 E3060 - 12 -...
  • Page 13: Side Reflection System

    Side Reflection System Reflection Sheet (Lamp + Reflector) Ad Film Light Reflection Sheet - 13 -...
  • Page 14: Power Connection

    Power Connection AC power at 100-240V, 50-60Hz 1. POWER ON/OFF SWITCH 2. POWER IN 3. POWER OUT 4. DMX IN 5. DMX OUT USB PORT (for ADMINISTRATOR ONLY) (Do not connect USB without administrator's permission.) 1. Observe the proper voltage range 2.
  • Page 15: Dmx Connection

    DMX Connection 3-pin or 5-pin XLR sockets are equipped for DMX input and output, depending on user needs. Connect the controller to a lighting, or lighting fixture to other lighting fixture. If user uses a standard DMX controller, the DMX output of the controller can connect directly to the DMX input of the first fixture in the DMX chain.
  • Page 16: Unlocking

    Unlocking Main Screen (Locked) Fixture ID Screen (Locked) When the fixture is turned on, If the power is turned off and then on again the Smart Touch screen automatically locked. while the fixture ID number screen is displayed, To unlock the touch screen, the fixture ID lock screen will appear.
  • Page 17: Main Screen Instruction

    Screen Instruction Current Mode Display DMX MODE or USER MODE or SERIAL MODE. Wirelss Signal sensitivity is displayed in % only when set to Wireless Signal (Option) ‘Wireless Enable’. DMX512 Address Display current DMX512 Address. Brightness (Intensity) Displays the brightness value(0~100%) of the equipment. CCT (Correlated Color Displays the color temperature of the equipment.
  • Page 18: Mode Change

    [Setting] Mode Change - DMX Mode It is used to adjust by DMX512 signal. - User Mode It is used when the user directly manipulates the equipment. - Serial Mode It is used for maintenance. ■ DMX Mode → User Mode When in DMX mode, user can change to user mode by adjusting the brightness in 'Setting - Brightness'.
  • Page 19 [Setting] Channel Mode Change ■ Channel Mode Change User can change the channel by selecting 'Current channel mode' in main screen or ‘DMX512 - Channel selection - DMX address' in setting. Pressing the icon in 'Channel Mode' displays information for each channel. - 1 (1 Ch mode) : Dimming - 2 (2 Ch mode) : Dimming, CCT - 19 -...
  • Page 20: Dmx512 Address Setup

    [Setting] DMX512 Address Setup ■ DMX512 Address Setup in the Main Screen Touch 'DMX512 Address' on the main screen to switch to the input window. 001~512 value can be entered. Press icon to save the DMX512 adress and move to the main screen. Also, the value can changed by RDM.
  • Page 21: Brightness(Intensity) Adjust

    [Setting] Brightness & CCT Adjust ■ Brightness(Intensity) Adjust The number indicates the current brightness value of the fixture and is displayed from 0 to 100%. Touch ’Intensity' on the main screen or the setting screen to adjsut the brightness value. Touch the gradient bar to apply it close to the desired value, and then touch to set the correct value.
  • Page 22: Fixture Id Setup And Change

    [Setting] Fixture ID Setup and Change ■ Fixture ID Setup and Change Touch on the main screen, the ID is displayed large on the screen, and touch the number to switch to the input window. It is a number for the management of the equipment and can be changed by the user. User can enter the value from 001~999, and touch after input to switch to the main screen.
  • Page 23: Lcd Off Setup

    [Setting] LCD Off Setup & LCD Rotation Setup ■ LCD Off Setup Touch 'LCD Off Setup' on the setting screen to display the above selection screen. - LCD Off Enable : The screen automatically turns off after 30 seconds, if there is no touch operation. - LCD Off Disable : The screen stays on all the time.
  • Page 24: Rdm Setup

    [Setting] RDM & Dimming Speed Setup ■ RDM Setup Touch ‘RDM Setup' on the setting screen to display the above selection screen. - RDM Enable : Enable RDM communication function. - RDM Disable : Disables RDM communication function. (Default) ■ Dimming Speed Setup Touch ’Speed Setup' on the setting screen to adjsut the dimming speed value.
  • Page 25: Master Setup

    [Setting] Master & Wireless Setup ■ Master Setup Touch ‘Master Setup' on the setting screen to display the above selection screen. Master setting allows user to synchronize and control all fixtures without a console connection - Master Enable : Enable Master function. - Master Disable : Disables Master function.
  • Page 26: Error Information

    Error Information Temperature Detects the temperature of the current fixture(LED, drive, housing) and displays it on Sensor the Smart Touch LCD screen. 0˚C or less is white, 0~69˚C is yellow, and 70˚C or more is red. If the temperature exceeds 78˚C, 'Temperature Error !!' and 'Please Check Device !!' will be repeatedly displayed, and the actual LED output will be 60%.
  • Page 27: Dmx Protocols

    DMX Protocols MODE #1 DMX Value Function MODE #2 DMX Value Function MODE #2 DMX Value Function 0~255 76~79 3850K 168~171 5000K CHANNEL 1 Dimmer 0~100% CHANNEL 2 CHANNEL 2 80~83 3900K 172~175 5050K 84~87 3950K 176~179 5100K MODE #2 DMX Value Function 0~255...
  • Page 28: Rdm Protocols

    RDM Protocols(1/3) Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_VERSION_LABEL DMX_START_ADDRESS IDENTIFY_DEVICE DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SENSOR_DEFINITION SENSOR_VALUE DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS_MESSAGES Lamp Controls Control Property Value (Example) Description User Settings Remarks Identify On Device identification action active Enable Identify device = Same as On Identify Off...
  • Page 29 Device Property Value (Example) Description Setting Device Model Description E2440 Model number of the device Disable Manufacturer Label ALPHA LITE Name of the manufacturer Disable ex) Input : BASE123 ►Name : BASE123 Device Label BASE123 Fixture name and management number Enable ►Management # : 123...
  • Page 30 RDM Protocols(3/3) Sensor Device Sensors Value (Example) Description User Setting Remarks Sensor Temp 64 ˚C Current fixture temperature Disable Error Message Condition Level Description Display Sensor Over Temp Warning Orange message Fixture temperature 78 ~ 85˚C Sensor Over Temp Error Red message Fixture temperature over 85˚C Table 1.
  • Page 31 LED Intelligent Lighting Solution For more information and questions, please visit our website or call. ALPHA LITE Co., Ltd. Floor, 5-8, Gyeongin-ro 88-gil, Yeongdeungpo-gu, Seoul, Republic of Korea, 07363 Email hello@alpha-lite.net (+82) 2-6317-0464 (+82) 2-2039-0464 www.alpha-lite.net...