This product (Model BH-101G0_0000) is a Supervisory
Controller that collects information about a primary device
(such as a controller) and provides that information to the
Client PC in savic-net G5, Azbil Corporation's building
management system.
This product receives point information from the primary
device through periodic scan or state change notifi cations
and accumulates and manages various kinds of control-
related data.
In addition, the software that can be downloaded from this
product allows you to monitor its state using graphics and
lists, set up several different kinds of controls including
interlock controls and scheduling, view data such as
charts as well as daily, weekly, monthly and yearly reports,
and perform other operations from the Client PC.
This product can also provide information to a third-party
BACnet device.
„ Features
Any combination of the following applications is available
as required.
• Equipment status monitoring
This product monitors up to 5000 points of the data
below.
It is possible to connect up to 30 Supervisory Controllers
to monitor up to 150,000 points.
Each Supervisory Controller can also be confi gured
for redundancy. (If a redundancy confi guration is
implemented, up to 60 Supervisory Controllers can be
connected.)
• Point information in the primary device
• Direct inputs to ensure immediate detection of
power supply state and fi re alarms from a building
• Comprehensive control
This product comprehensively controls the devices
connected to the system to realize comfort, safety, and
energy effi ciency.
Supervisory Controller
Specifications/Instructions
• Data management
This product stores and manages the following data:
• Data collected from the devices connected to this
product
• Data transmitted from the devices connected to
this product
• Data that has been processed for daily, weekly,
monthly, and yearly reports based on the collected
and transmitted data
• Data visualization
By using the software that comes with this product,
you can display graphics, charts, and daily, weekly,
monthly, and yearly reports on the screen of a Client
PC or output them to a fi le.
© 2017–2020 Azbil Corporation. All Rights Reserved.
1
AB-7333

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BH-101G0W0000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Azbil BH-101G0W0000

  • Page 1 This product (Model BH-101G0_0000) is a Supervisory Controller that collects information about a primary device (such as a controller) and provides that information to the Client PC in savic-net G5, Azbil Corporation's building management system. This product receives point information from the primary...
  • Page 2 • Aeronautical/aerospace machines  For system design, application design, instructions Alerts users that improper handling may for use, or product applications, please contact Azbil cause minor injury or material loss. Corporation. CAUTION Azbil Corporation bears no responsibility for any result, or lack of result, deriving from the customer's use of the „...
  • Page 3 AB-7333  WARNING  CAUTION Install this product in a location out of Strip the insulation from cables as speci-  reach of unauthorized people. (e.g. Inside fied in this manual.  of the control panel with a lock) If the length of exposed wire is longer than Electric shock Failure to do so might cause electric shock.
  • Page 4 AB-7333 „ System Configuration Client PC Network Attached Third-party Network Attached Storage Storage BACnet/IP device Switching hub Switching hub Switching hub (Redundancy) Supervisory Controller Supervisory Controller Third-party Supervisory Controller Model BH-101G Model BH-101G BACnet/IP Model BH-101G (Active) (Standby) device ETHERNET (BACnet/IP, Modbus/ TCP, etc.). The communication distance between each device and the switching hub must be 100 m or less.
  • Page 5: Replacement Parts

    50 devices/channel (VAV/FCU Controllers, Compact Remote I/O Modules, etc.) There are restrictions on the General Controller that up to 70 secondary devices or up to 50 of the sum of Azbil’s VAV and FCU controllers can be connected. There are no restrictions on the Advanced Controller for Chiller Units, and Advanced Controller for Pump Units.
  • Page 6 AB-7333 „ Specifications z Basic Specifications Item Specification Power supply Rated voltage 100–240 V AC, 50 Hz/60 Hz specifications Operating power supply 90–264 V AC, 50 Hz/60 Hz ± 3 Hz voltage Inrush current 50 A max. (240 V AC) Power consumption 60 VA max.
  • Page 7 AB-7333 z Specifications for Inputs and Outputs Item Specification Digital Number of input terminals input Voltage 12 V DC -10/+15 % (with voltage contact) Current 10 mA DC typ. Connected device output method Dry contact or open collector Digital Number of output terminals output Relay output Output method...
  • Page 8 AB-7333 „ External Dimensions Figure 2. External dimensions (mm) „ Name of Parts ETHERNET LAN1 ETHERNET LAN2 USB 2.0 (not used) (not used) Line output (not used) USB 3.0 (not used) Display port (not used) Operation state LEDs Communication LEDs 7-segment LED User operation switch DO status LED...
  • Page 9: Installation Location

    AB-7333 „ Installation  WARNING  Install this product in a location out of reach of unauthorized people. (e.g. Inside of the control panel with a lock) Failure to do so might cause electric shock. Electric shock  CAUTION  Do not drop this product.
  • Page 10: Installation Method

    AB-7333 z Installation Method Fan (Model 83978069-101) • Install one unit at the top of the panel cabinet. 700 mm 600 mm Supervisory Controller 215 mm from Model BH-101G0_0000 the panel cabinet • Install it at the top of the panel ceiling (highest 50 mm level of the...
  • Page 11 AB-7333 <Installation on a DIN Rail> <Direct Installation with Screws> Pull down the two DIN holders on the bottom of the Install the product on the wall or panel wall using four M4 device. L=8 screws or four studs with female threads. Make four screw holes in the installation locations.
  • Page 12: Notes On Wiring

    AB-7333 „ Wiring z Wiring of Power Supply Terminal Block  WARNING Screw connectors are used. Be sure to ground the product with ground  resistance of less than 100 Ω. Improper grounding may cause electric Ground shock or malfunction. Before wiring or maintenance, be sure to ...
  • Page 13 AB-7333 z Wiring of the Direct Input Terminal Blocks and Insert the cable whose wire was exposed in step (1) Direct Output Terminal Block into the cable clamp and tighten it by turning the screw above the cable clamp to the right with a screwdriver.
  • Page 14 AB-7333 „ Handling <Direct Input Terminal Blocks> Do the following before turning the power on. Check again that the wiring is done correctly. Terminal Connector Description (example usage) Pin No. (2) Peel off the protective sheets before powering the DI CH1 (fire inputs) device on.
  • Page 15 AB-7333 „ Power On/Off  WARNING  Do not touch electrically charged parts. Doing so may cause electric shock. Electric shock IMPORTANT!! • Do not test the withstand voltage of this product. Doing so may cause the device to fail. •...
  • Page 16 (Lithium ion capacitor module being charged) Not lit Power OFF System error indicator ERROR Abnormal Flashing Note: Contact Azbil Corporation. Not lit Normal Active indicator for redundant Green The device is operating (active). product configuration Not lit The device is for backup (standby).
  • Page 17: Notes On Cleaning

    Doing so may cause electric shock. Clean the fan according to "● How to Clean <How to Electric shock Clean Built-up Dust>." If this does not solve the problem, contact Azbil  CAUTION Corporation. • If the product has an unusual odor, possible causes ...
  • Page 18 AB-7333 z How to Remove and Attach the Fan Assembly Remove the fan while this product is operating. (3) Pull the connector out of the fan assembly.  CAUTION Connector Before touching this product, be sure to Fan assembly remove any static electrical charge from ...
  • Page 19: Replacement Procedure

    AB-7333 z Replacement Procedure (5) Insert a new clock battery in the same place as the <Clock Battery (Lithium Battery)> original one. Handling precautions • Replace the clock battery while the device is turned on (if the battery is removed while the device is turned off, time data will be lost.).
  • Page 20 As an electromagnetic wave equipment for office use (Class A), this equipment is intended to use in other than home area. Sellers or users need to take note of this. * ACTIVAL, ACTIVAL +, Infilex, and savic-net are trademarks of Azbil Corporation. * BACnet is a trademark of American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE).

This manual is also suitable for:

Bh-101g0n0000

Table of Contents

Save PDF