FlowCon FN.0.2, FN.0.4 and FN.1.2 Actuators
1B95080 - 08/2019-2
Installation and Operation Instruction
The actuator types FlowCon FN.0.2, FN.0.4
and FN.1.2 are electrical actuators. FN.0.2 is
24V modulating and FN.0.4 is 24V 3-point float-
ing and 2-position. FN.1.2 is 24V modulating and
2-position failsafe version.
Fitting and Re-fitting
Do not connect power to the actuator unless
the actuator is already fitted on the valve
and NEVER install the actuator in closed
position - this may damage the valve. Actu-
ator is supplied in open position to ensure
easy commissioning of the system.
Mount the actuator on the valve and finger
tighten the connection union. Do not use addi-
tional tools. In case the actuator will have to be
removed, it is recommended to electrically open
the actuator by activating DIP switch #6 for eas-
ier removal. Hereafter finger loosen the connec-
tion union. Again, no need for additional tools.
Please make sure that the actuator is electrically
opened, before re-fitting it on the valve.
Figure 1
This paper is a supplement to the FlowCon General Instruction
Latest release of any FlowCon material is available on www.flowcon.com
Figure 2
Orientation
Upside-down installation is allowed (reduced IP
rating applies) along with the standard horizontal
and vertical installation.
360º
Figure 3
Page 1 of 4

Advertisement

loading

Summary of Contents for FlowCon FN.0.2

  • Page 1 Please make sure that the actuator is electrically opened, before re-fitting it on the valve. Figure 3 Figure 1 This paper is a supplement to the FlowCon General Instruction Page 1 of 4 Latest release of any FlowCon material is available on www.flowcon.com...
  • Page 2 Power 24V AC/DC mode. Ground/common Feedback ground 0V DC This paper is a supplement to the FlowCon General Instruction Page 2 of 4 Latest release of any FlowCon material is available on www.flowcon.com...
  • Page 3 Normally Open Normally Closed Control signal 2-10V Control signal 0-10V Auto cycle ON Auto cycle OFF This paper is a supplement to the FlowCon General Instruction Page 3 of 4 Latest release of any FlowCon material is available on www.flowcon.com...
  • Page 4 Blinking green (closing point adjustment) Electrical override mode Blinking red/green Blinking red/green Blinking red/green Failsafe mode This paper is a supplement to the FlowCon General Instruction Page 4 of 4 Latest release of any FlowCon material is available on www.flowcon.com...