TO MAINTAIN THE EXTRACTOR
AFTER EACH USE:
1. Drain recovery tank after each use.
2. Remove all soil and debris from the
recovery tank.
3. Flush out recovery tank with clean water.
END OF DAY MAINTENANCE:
1. Pour 2 gallons of clean hot water – not
exceeding 120°F - in the solution tank.
Turn the pump ON and flush the entire
system for about a minute to prevent
alkaline build-up. Using hose provided,
drain tank into a bucket or floor drain.
2. Relieve the brush pressure. Clean debris
from around the brush and brush tunnel.
This will be easier if you remove the brush.
3. Clean vacuum shoe with stiff wire.
CAUTION: DO NOT leave water in tanks over
night or store with water in tanks.
AFTER REPEATED USE:
Spray Nozzles: Remove and clean the spray
nozzles of any debris or build-up. Replace when
necessary. When replacing fitting nozzles, they
should be positioned parallel to the brush.
Solution Filter: After 4 to 6 uses, remove the in-
line solution filter (located in solution tank) and
clean with a small brush and rinse.
Safety, Operation and Maintenance Manual for TW Compact; Version 1.0
Brush: Clean the brush of any debris.
Solution Lines and Fittings: Flush extractor at
least once a month with a solution of 1 part water
to 3 parts white vinegar in order to neutralize the
alkaline residue left by the cleaning solution.
Accessory
Disconnect:
lubricant to prevent coupler from sticking.
Pump: Follow procedure used above on solution
line and fittings to flush out pump. In order to
service the pump, contact the factory or authorized
service center.
Vacuum Motor: Carbon brush mechanism holder
should be replaced after operating 700 hours or
when the carbon brushes are worn down to ⅜" in
length. Replace both brushes at the same time.
TO REPLACE AND INSTALL BRUSH:
1. Remove the screw next to the brush
pressure lever.
2. Remove the brush holder and brush.
3. When installing the brush, make sure the
centering pins on the brush are properly
placed in the holes of the drive pulley.
4. Re-insert
the
replace the screw tightly.
Spray
with
silicone
brush
holder
securely,
8
Need help?
Do you have a question about the TW Compact and is the answer not in the manual?