Visual Studio .NET, MATLAB
int SD_Module::getSlot(int index);
Python
int SD_Module::getSlot(int index);
LabVIEW
getSlot.vi
M3601A
Available: No

2. 4. 2. 8 PXItriggerWrite

This function sets the digital value of a PXI trigger in the PXI backplane. This function is only
available in PXI / PXI Express form factors.
Parameters
Name
Inputs
moduleID
nPXItrigger
value
errorIn
Outputs
moduleIDOut (LabVIEW only) A copy of moduleID
errorOut
C
int SD_Module_PXItriggerWrite(int moduleID, int nPXItrigger, int value);
Keysight M31XXA/M33XXA Digitizer User's Guide
Description
(Non-object-oriented languages only) Module identifier, returned by function
PXI trigger number
Digital value with negated logic, 0 (ON) or 1 (OFF)
(LabVIEW only) If it contains an error, the function will not be executed and errorIn will be
passed to errorOut
Error Codes (page 81)
2 Software Tools: M31/M33XXA Digitizers
open (page 27)