18.7 Quick Connect Multi System Installation

• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect
Cord. Unit's MAX Btuh must be same in order to quick connect. e,g. When installing PV199DV (GHQ-
C3201WX-FF PB US), you must install UT199DV (GQ-C3260WX-FF PB US).
• The Quick Connect Cord is 6 ft. (2m) long. Install the units 3-18 in. (75-457 mm) apart from each other to
ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach, but the water
temperature may also become unstable because of the difference in pipe length between the two units).
System Diagram
PV199DV
(Combi Boiler)
Operation Display
Quick Connect
Cord
Cord
Connector
To Auto Feeder
Typical Plumbing
Make this distance as
short as possible.
The hot water temperature
will become unstable as
the pipe length increases.
Quick Connect Cord
Wire connection
Solenoid Valve (refer to page 52)
UT199DV
Solenoid Terminal
(Refer to page 52)
Cord
Connector
Wire Connection
S
Solenoid Valve
Distance on sides
3 - 18 in. (75 - 457 mm)
To drain outlet
NOTE This system is operated by
• Insulate the hot water piping to
prevent heat loss. Insulate and apply
heating materials to the cold water
supply piping to prevent heat loss and
Intake
freezing of pipes when exposed to
Exhaust
excessively cold temperatures.
Service Valve Kit with Pressure Relief Valve*
* Service Valve Kit with Pressure Relief Valve is
necessary for flushing the Plate Heat Exchanger.
This allows for easy flushing of the system.
Union
Gas Valve
To drain outlet
the Combi Boiler's Operation
Display.
Don't connect the remote
controller to the water heater.
The UT199DV remote controller
(Included Accessory) will be
required to troubleshoot, make
sure the customer keeps the
remote for future use.
Gas Supply
Cold Water Supply
DHW Supply
Leave enough clearance around the
plumbing to apply insulation. It will be
necessary to add bends to the piping to
ensure that this clearance is available.
The backflow preventer should be placed
upstream
of the cold water branch.
DHW Cold Water Supply
DHW Supply
Size the piping to allow for the
maximum flow rates of the units.
Plumbing Applications
79