6. Secure the Quick Connect Cord with a clamp.
7. Reattach the front cover (4 screws).
Clamp
Connector
Ground Wire
Wiring Throughway
* Connecting the cord to the other unit, refer to
the unit's Installation Manual.
Specifications for a solenoid valve
• Pipe size: 3/4 in.
• Voltage: 120 VAC
• Current: Max 1.5 A
• Normally closed (Closed when de-energized)
* A slow-closing solenoid is recommended to
prevent water hammer from occurring.
Check the Quick Connect Multi System Installation
After install the Quick Connect System, do the
following step to check proper installation.
1. The ON/OFF button is ON.
2. Press the MAINTENANCE button.
(td: technical data)
3. Press the ENTER button to view the "Technical
Data".
(Data No. 03)
52
Connecting Electricity
Circuit Board
Quick Connect Cord
[CN238]
Solenoid Valve
SV
2 sec.
(e.g.: 100)
buttons to navigate through
4. Press the
/
the "Technical Data".
* Pressing and holding the button to change it
in increments of 10.
5. Check the Quick Connect Cord connection.
• Select
appears.
• If
Connect Cord connection.
6. Open the front cover and a hot water fixture.
Press and hold the "Mode" and "Minimum"
Buttons on the Circuit Board simultaneously
for more than 3 seconds.
Check step 7 within 30 minutes.
Operation Display
Mode Button
Minimum Button
7. Check the Combi Boiler operation.
• Select
appears.
• If
and the Solenoid Valve.
When you are done, press the "Mode" Button
for more than 3 seconds, then close the hot
water fixture and the front cover.
8. Press the BACK button twice or let it sit for
approximately 10 minutes to return to the
home screen.
NOTE The Water Heater can be set as the
master unit in the quick connect
multi system. The master unit
controls the DHW ON/OFF status of
the Combi Boiler in the system. Once
turned on by the master unit, the
Combi Boiler will operate in stages
to satisfy the DHW demands.
* Please contactt Pavilion Customer Center at
1-855-443-8468 if you have any questions or
concerns.
, then check
appears, check the Quick
Circuit Board
MODE
, then check
appears, check the plumbling