Do not orient glands upward to prevent water from entering via
Never pull the cable or bend it extremely. Wiring requires great
Maintenance and adjustment requires enough space in the
When the temperature of the measuring fluid exceeds the
When the temperature of the measuring fluid falls below ambient
Wind the tape around the tapered male pipe thread to prevent
When a straight pipe thread is used, check the packing and seal
If there is a risk of surge pressure, use the throttle fitting and
■7.2 Precautions for Possible Water Sprinkling
Install the product so that the gland part (cable outlet) faces
When installing the cable, move it down to the bottom first as
For installation of conduit, do the same to prevent water from
cables.
care so that the self-weight of the cable is not applied to the
product.
surroundings.
operating temperature range, take heat release measures by
using a cooling system or installing the pipe syphon to mitigate
the effects without introducing the measuring fluid in the KH15
body.
temperature (or when you see temperature difference between
the main unit and fluid), take measures against condensation
such as a pipe extension so that the temperature of the
measuring fluid is nearly equal to ambient temperature of the
main unit.
leakage.
surface for dust, contamination or flaws to prevent leakage.
dampener.
downward to prevent water from entering through there as
shown in the figure below (recommended installation direction).
Tighten the gland securely to prevent the intrusion of water (See
"8.1 Wiring").
shown in the following figure, bend it in a circular pattern a few
times and then install it upward so that water hardly enters or
accumulates inside the cable (move the cable down to the
bottom first before installation regardless of the mounting
orientation).
entering.
CAUTION
CAUTION