Nagano Keiki KH15 Series User Manual

Waterproof pressure transmitter

Advertisement

User Manual for KH15
Waterproof Pressure Transmitter
KH15-J□□/K□□
1
TY-KH15-007A Rev.2
7.3

Advertisement

Table of Contents
loading

Summary of Contents for Nagano Keiki KH15 Series

  • Page 1 User Manual for KH15 Waterproof Pressure Transmitter KH15-J□□/K□□ TY-KH15-007A Rev.2...
  • Page 2: For Proper And Safe Use

    FOR PROPER AND SAFE USE Thank you for purchasing the KH15 waterproof pressure transmitter. To use this product safely and properly, read this user manual carefully. This is a pressure transmitter that can support a wide range of cases where components such as liquid or gas are used. Incorrect use of it causes failures, which may result in damage including faults or accidents.
  • Page 3: Precautions For Handling Product

    ■Precautions for Handling Product WARNING Do not give excessive load, vibration or shock. ● Damage to the product and release of a measured object may be caused, which results in injury or damage to the surrounding environment. Repeated applied pressure shall be within the rated pressure ●...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS FOR PROPER AND SAFE USE ........... 2 ■Definition of Safety Terms ..................2 ■Description of Graphic Symbols ................2 ■Precautions for Handling Product ................. 3 TABLE OF CONTENTS ..............4 1. INTRODUCTION ............... 6 2. PRODUCT OVERVIEW ............. 6 ■2.1 Overview ......................
  • Page 5 11. STORAGE ................19 ■11.1 Precautions for Storage ................19 12. MAINTENANCE ..............19 ■12.1 Periodical Inspection ..................19 ■12.2 Adjustment ..................... 20 13. PRODUCT WARRANTY/ EXPORT ADMINISTRATION REGULATIONS ..................... 22 ■13.1 Product Warranty ..................22 ■13.2 Export Administration Regulations ............. 22 14.
  • Page 6: Introduction

    1. INTRODUCTION Check the specifications of the delivered model. Incorrect pressure range, power supply or output will cause an accident. Make sure to use a model of the designated specifications in a location that meets your use conditions and that it is properly wired and installed. 2.
  • Page 7: Model Number Configuration

    2.2.2 Configuration example of above (4 to 20 mA DC output) Regulated circuit Pressure detecting section Output circuit +CHECK (+CH) < Figure.2-2 > 3. MODEL NUMBER CONFIGURATION This chapter describes the model number configuration. □ □ □ KH15 - Seal system 3: O-ring Type 4: All-welded (SUS630 (17-4PH))
  • Page 8: Specifications

    4. SPECIFICATIONS <Table 4-1> ■4.1 Product Specifications Item Details □□ □□ □□ Model number KH15- KH15- Pressure sensor seal O-ring type Weld type system 0 to 0.1, 0 to 0.3, -0.1 to 0 MPa -0.1 to 0.5 => -0.1 to 2 MPa Pressure range -0.1 to 0.1, -0.1 to 0.3 MPa 0 to 0.5 =>...
  • Page 9: Dimensions

    *1 Do not seal the cable end with taping or adhesive during wiring as it will block atmospheric pressure introduced via the cable. Avoid using a cable with poor ventilation (no clearance within the cable). *2 Max. allowable pressure is the upper limit of pressure value which may safely be applied to the product and remain in specification once pressure is returned to the rated range with a couple of times overpressurization for about 10 minutes.
  • Page 10: Kh15-K□□ (Large Terminal Box)

    ■5.2 KH15-K□□ (large terminal box) 22 X 25.4 HEX. < Figure 5-2 > Y-KH15-007A Rev.3...
  • Page 11: Transportation And Unpacking

    6. TRANSPORTATION AND UNPACKING ■6.1 Precautions for Transportation (1) Do not apply vibration as much as possible in transporting the product, as is the case with other electric meters. (2) Never hit or drop the product. ■6.2 Precautions for Unpacking (1) Check the appearance of the carton before unpacking.
  • Page 12: Precautions For Possible Water Sprinkling

    CAUTION  Do not orient glands upward to prevent water from entering via cables.  Never pull the cable or bend it extremely. Wiring requires great care so that the self-weight of the cable is not applied to the product. ...
  • Page 13 CAUTION  Atmospheric pressure is introduced into an instrument via the cable. If the cable is pressed due to a clamp, bush, or extreme bend in the middle of the cable, or if the cable is long, the exhaustion of pressure takes time. In this case, an output error may be caused because of pressure within the case or a change in temperature.
  • Page 14: Wiring And Connection

    8. WIRING AND CONNECTION ■8.1 Wiring 1) Refer to the table below to obtain a suitable shielded cable. Gasket inner dia. Suitable cable dia. Model number Terminal opening size (mm) (mm) φ7 φ6 to 7 □□ KH15-J- (standard) G3/8 terminal box φ8 φ7 to 8 (small)
  • Page 15 CAUTION  Use a dedicated tool to peel the coating to avoid damage to the cable core.  Be careful if the shielded wires do not extend the sheath end face.  Atmospheric pressure is introduced into an instrument via the cable.
  • Page 16: Waterproofness Of Wire Inlet

    5) Secure the wire to the terminal block. □□ The recommended tightening torque for KH15-J terminal block: 0.4 N・m □□ The recommended tightening torque for KH15-K terminal block: 0.5 N・m CAUTION  Never connect the wires with moisture adhering to the product. Penetration of moisutre or other substances inside the product will cause malfunction.
  • Page 17: Wiring Diagram And External Connection

    ■8.3 Wiring Diagram and External Connection (1) Wiring diagram 2-wire system 3-wire system Terminal block Terminal block AWG24 to 12 AWG24 to 12 Terminal Terminal block block < Figure 8-4 > (2) Examples of external connection < 2-wire system (4 to 20 mA DC) > Ammeter to monitor output KH15 Power supply...
  • Page 18: Operation (Energization)

    * When using the same power supply to connect equipment that causes surge or other phenomena, a varistor or the like should be connected to protect the transmitter. CAUTION  Before installation, check the rated value specified for this product to determine the rated value of the power supply to use. Internal resistance of equipment to be connected should be within the rated load resistance of the product.
  • Page 19: Storage

    Induction noise • Keep the product away from the wiring carrying high current. • Keep the product away from electrically charged machines or objects. Conductive noise • Use the stable power supply that is difficult to generate noise. • Install power supply or output measurement equipment in an environment that is impervious to being affected by noise.
  • Page 20: Adjustment

    Current output can be checked with a check terminal (+CH) without removing any wiring. Use an ammeter with an internal resistance of 10Ω or less during checking. CAUTION  Avoid electrostatic charge.  To clean the appearance of the product, use a water-soaked soft cloth.
  • Page 21 12.2.1 Zero adjustment Turn the zero trimmer with a slotted screwdriver to perform zeroing. A positive pressure range and compound range are adjusted differently as shown below. < Positive pressure range > Adjust output in a vented (unpressurized) state to 4 mA DC for the current output product, and to 1V DC or 0V DC for the voltage output product.
  • Page 22: Product Warranty/ Export Administration Regulations

    If the delivered product within the warranty period (one (1) year from the delivered date) is judged as a nonconforming product according to "Defect due to the design or manufacturing by Nagano Keiki Co., Ltd.", they are repaired or replaced with conforming products free of charge.
  • Page 23 ■MEMO Y-KH15-007A Rev.3...
  • Page 24 For other questions, contact our sales office nearest you, or call the number below. User Manual for KH15 Waterproof Pressure Transmitter June 2020, Rev. 3 Website: http://www.naganokeiki.co.jp/?lng=eng NAGANO KEIKI CO., LTD. Head office: 1-30-4, Higashi-magome, Ota-ku, Tokyo 143-8544 Phone: +81-3-3776-5328 Fax: +81-3-3776-5447...

Table of Contents