28 Commissioning

Commissioning test for FSE-31

1. Make sure that only one safety encoder is connected to the
FSE-31 module and that it is connected to connector X31.
2. Make sure that only one FSE-31 module is connected to the
drive.
3. Make sure that the installed encoder type, pulse count, and
safety rating match the system design specification.
4. Make sure that the installed encoder is suitable for the
application and that the encoder is compatible with the FSE
module. See section
5. Make sure that the encoder is installed according to the
instructions of the safety encoder manufacturer and according
to the wiring instructions of this manual.
6. For the encoder interface configuration and validation
instructions, see FSO-21 safety functions module user's
manual (3AXD50000015614 [English]).
Supported safety encoders
on page 34.