Level 2 Parameters Setting - Global BH 1793 Instruction & Parts Manual

Computerized control system for square buttonhole machine
Table of Contents

Advertisement

Mode Setting
No.
start distance
Input the distance for needle thread trimmer motor to
release the trimmer at sewing start.
U24
Bobbin thread trimming release motion
start distance
Input the distance for bobbin thread trimmer motor to
release the trimmer at sewing start.
U25
Counter updating unit
Update Unit in sewing counter
U26
Forbid Changes at Counter
U27
Operation of machine at counter reaching set value
U50
Voice of Buzzer
OFF:Buzzer off
PAN:Control Panel Voice available
ALL:Voice of Control Panel and buzzer available
U100
Back Light Auto Off
OFF:No Auto Off
ON: Auto Off
U101
Back Light Off Wait Time
U200
Language Setting
U201
Select Language at Power-on

7.3 Level 2 Parameters Setting

① Set Parameter
n the interface of Mode Setting Level 3,
press
to enter the interface for setting
parameters of Level 2 (as shown in the right
figure). For the operation methods, please take the
description in 7.2 Level 1 Parameter Setting for
reference
When some parameters are changed, the system
will display the "Modified" in the parameter
setting interface.
Press
to quit the parameter setting interface
Computerized Control System for Square Buttonhole Machine
Parameter
78
Range
Unit
0~15.0
0.1mm
1~30
1
ON、 OFF
ON 、OFF
OFF、PAN、
ALL
ON、OFF
1~9
1
Chinese,
English,
Turkish
ON、OFF
Default value
1.5mm
1
OFF
OFF
ALL
OFF
3s
Chinese
OFF

Advertisement

Table of Contents
loading

Table of Contents