SAFETY DURING INSTALLATION
Electrical
l
A protective electrical ground connection to a reliable earth ground
is essential for safe operation. Without one, all accessible conduc-
tive components (including knobs and controls that appear insu-
lated) can render an electric shock.
.
A disconnect switch with lockout capability must be provided be-
tween the power source and the equipment.
l
The power supply wire gauge and insulation must be sufficient to
meet the temperature and power requirements.
l
Only fuses of the correct type voltage rating and current rating
should be used. Refer to the equipment parts list for fuse recom-
mendations. Using incorrect or non-recommended
fuses can
present a fire hazard.
Pneumatic
Install a lockout, three-way, manual valve in the air supply line to the
filter/regulator. This valve makes it possible to relieve air pressure
and lock out the pneumatic system before undertaking maintenance
or repairs.
Gas System Installation
(FoamMelt@ applicators and nitrogen blanket kits only)
Cylinders of compressed gas are under high pressure and can present
significant safety hazards if handled improperly. Refer to OSHA
General Industry Standards, paragraphs 1910.101,1910.166
and
1910.167 for safety precautions that apply to the use, handling, and
storage of compressed air.
SAFETY DURING OPERATION
DO NOT operate Nordson equipment under the following conditions:
.
At a pressure higher than the rated maximum working pressure of
any component in the system.
l
Near volatile or otherwise explosive gases or materials.
l
Without the covers, panel and safety guards properly installed.
issued 3/93
0 NORDSON CORPORATION 1993
All Rights Resetved