For an ext. Presentation unit with SW mode 1728 - 1582, the address
can be set to 01-08. (Default is "01".)
Scroll to the wanted address with the push button "P1" (black).
Store the selected address with the push button "P2" (yellow) and the
unit will automatically restart and enter its normal operation mode.

Address setting mode via the c.i.e.

One specific ext. Presentation unit or all the ext. Presentation units
connected to the same line (RS485) can, in normal operation, from the
c.i.e. receive a command and get ready for the "Address setting"
directly. This is done via menu H5/A9, see Operating instructions for
the system respectively.

Flow chart

On the following page is a flow chart, showing the SW mode setting,
Language setting, Address setting, etc.
13
If the unit has no SW mode, i.e. "Not selected", it will not enter its normal
operation mode after the restart but start from the beginning again, ready for
the SW mode setting.