Specifications - Tripp Lite SM750XLNAFTA Specifications

Smart pro expandable tower ups system - nafta assembled version of smart750xl

Advertisement

91-145V
Includes 8 fully-protected NEMA 5-15R output receptacles arranged in a single load bank that can be powered off and back on again via
software interface
PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification,
event logging and running user-defined script commands
Offers simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP* interfaces (*requires optional
SNMPWEBCARD), or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software.
Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage,
DC battery voltage and remaining battery capacity
Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for delayed or immediate reboot
of connected equipment
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by systematically restarting applications, operating
systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again (requires
optional WATCHDOGSW)
15 LEDs offer continuous detailed status information of UPS operating parameters and site power quality
Hot-swappable batteries allow on-site battery replacement without powering off connected equipment
2 year warranty with up to $250,000 connected equipment insurance

Specifications

OUTPUT
Output Volt Amp Capacity
(VA)
Output Watt Capacity
(watts)
Output power factor
Nominal Output
Voltage(s) Supported
Nominal Voltage details
Frequency compatibility
Output voltage regulation
(line mode)
Output voltage regulation
(Battery mode)
Built-in UPS output
receptacles
Basic PDU options
Metered PDU options
Switched PDU options
External PDU redundancy
options
Output AC waveform (AC
mode)
Output AC waveform
(battery mode)
INPUT
Rated input current (at
maximum load)
750
450
0.6
100V; 110V; 120V
120V default (voltage selection via back panel switches)
60 Hz
-13%, + 15%
+/- 5%
8 5-15R outlet(s)
PDU1215
(1U / 13 5-15R outlets);
PDUV15
(0U / 12 5-15R outlets)
PDUMH15
(1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*;
PDUMH15ATNET
(1U / 8 5-15R outlets)*;
*Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS
models only
Sine wave
Pure Sine wave
6.9A
PDUNV
(1U / 2 C19, 12 C13 outlets);
PDUMV15NET
(0U / 16 5-15R outlets)
PDU1415
(0U / 14 5-15R outlets);
PDUMV15
(0U / 16 5-15R outlets)

Advertisement