Download Print this page

Installation - ABB ACS580 Series Supplement Installation Manual

Enclosed drives
Hide thumbs Also See for ACS580 Series:

Advertisement

10
ACS580-0P

Installation

This information is unique to ACS580 input disconnect configurations (0P or
0P+F255). The ACS580 with Input Disconnect is an ACS580 AC adjustable
frequency drive packaged with an input disconnect switch or circuit breaker. Refer to
the
Installation
the warnings and instructions may cause a malfunction or personal hazard.
WARNING! Before you begin read
WARNING! When the ACS580 with Input Disconnect is connected to the line power,
the Motor Terminals T1, T2, and T3 are live even if the motor is not running. Do not
make any connections when the ACS580 with Input Disconnect is connected to the
line. Disconnect and lock out power to the drive before servicing the drive. Failure to
disconnect power may cause serious injury or death.
1. Install wiring
WARNING!
• Metal shavings or debris in the enclosure can damage electrical equipment and
create a hazardous condition. Where parts, such as conduit plates require cutting
or drilling, first remove the part. If that is not practical, cover nearby electrical
components to protect them from all shavings or debris.
• Do not connect or disconnect input or output power wiring, or control wires, when
power is applied.
• Never connect line voltage to drive output Terminals T1, T2, and T3.
• Do not make any voltage tolerance tests (Hi Pot or Megger) on any part of the unit.
Disconnect motor wires before taking any measurements in the motor or motor wires.
• Make sure that power factor correction capacitors are not connected between the
drive and the motor.
Enclosure Designation
Px1-1 & Px12-1
Px1-2 & Px12-2
Px1-3 & Px12-3
Px1-4 & Px12-4
PxB3R-1
PxB3R-2
PxB1-3 & PxB12-3
1) 100 HP @ 230V.
* Only available as ACS580 R2 Frame
** Only available as ACS580 R3 Frame
ACS580-0P
instructions on page 8, for all other information. Failure to observe
Safety instructions
Horsepower Range by Voltage Range
208V
1 to 5 HP
10 HP
15 to 20 HP
25 HP
1 to 10 HP
15 to 25 HP
30 to 100 HP
Supplemental Installation Manual for ACS580-0P
on page 2.
2
460V
575V
1 to 7.5 HP
N/A
10 to 15 HP
2 to 15 HP
20 to 30 HP
20 to 30 HP
40 to 60 HP
N/A
1 to 15 HP
2 to 15 HP
20 to 60 HP
20 to 30 HP*
1
75 to 200 HP
40 to 150 HP
Base Drive
Frame
R1
R2
R3
R4
R1-R2
R3-R4
R5-R8