Boost Function (Boost, Bos) - eQ-3 MAX! Operating Manual

Radio wall thermostat
Hide thumbs Also See for MAX!:
Table of Contents

Advertisement

Available languages

Available languages

• Confirm setting with the OK button.
Even in Auto mode the temperature can be changed with
this button at any time. However, the change will only be
maintained until the next phase the timer programme starts.
The Boost function can create the sensation of a rise in
room temperature to the human body. When activated the
radiator valve will immediately be adjusted to 80% valve
opening for 5 minutes (factory setting). The heating of a
room takes longer than 5 minutes but the radiated heat
from a radiator can be sensed immediately.
• To activate the Boost function press the OK but-
ton. Once the Boost time has completed the Wall
Thermostat will switch back to the previously ac-
tive mode (Auto/Manu) and the previously set
temperature.
• The Boost function can be deactivated at any time
by a renewed press of the OK button.
The count-down in second intervals of the remaining func-
tioning time (e.g "300" to "000") and
on the display.
The length and valve opening of the Boost function can be
individually adjusted as follows:
• Press the Menu button for more than 3 seconds.
• Select the "bOS" menu item with the (+) and (-)
buttons.
• Confirm the setting with the OK button.
19. Boost function (
, bOS)
BOOST
will be shown
BOOST
41