EDGE GROOMER REPLACEMENT CONT.
2. Lift off both old edge
groomers (T) and slide new
edge groomers into position.
(See Figure 35)
3. Reposition the bottom plate
and screw the four screws
back in.
HEADLIGHT
REPLACEMENT
CAUTION! Disconnect
the vacuum from
electrical outlet before
removing the lens.
1.
Using a Phillips screwdriver,
remove the two screws (Z)
from the lens (AA). Lift the
lens off the vacuum.
(See Figure 36)
2. Pull the old bulb (BB) straight
out of the socket and push
the new bulb straight into
the socket until it locks into
place. (See Figure 37)
Do not use excessive force.
3. Reposition the lens and
secure with the screws.
(See Figure 38)
OPERATING ISSUE
Vacuum won't turn on.
There is little to no suction.
Vacuum is hard to push.
Vacuum has a burning smell.
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
PAGE 7 OF 7
MAINTENANCE CONTINUED
Figure 35
T
Figure 36
Z
AA
Figure 37
BB
Figure 38

TROUBLESHOOTING

1.
Plug cord in firmly.
2.
Check fuse and breaker.
3.
Replace fuse or reset breaker.
4.
Allow vacuum to cool for 30 minutes.
1.
Clear any blockage in hose or base of vacuum.
1.
Move nozzle control knob to lower setting.
2.
Change filter bag.
3.
Replace belt.
4.
Replace brush roll.
1.
Move carpet height control to a higher setting.
1.
Check for clogs in hose and base of vacuum.
2.
Replace belt.
1-800-295-5510
uline.com
AGITATOR BRUSH ROLL REPLACEMENT
1.
Check the condition of the
brushes by placing the edge of
a card across the bottom of the
plate while turning the agitator
brush. (See Figure 39)
2. If brushes do not touch the card
the agitator brush roll needs to
be replaced.
3. To replace, remove the bottom plate, belt and agitator
brush roll. (See Belt Replacement, page 6)
4. Discard the old agitator brush roll and replace with a
new one.

CLEARING BLOCKAGES

NOTE: A blockage in the system can cause low
suction or pickup.
1. Check filter bag. Change if full.
2. Turn on vacuum. Check end of hose for suction.
a. If there is no suction, disconnect the hose and
check for blockage in the hose and tube.
3. Check for blockage at the connection at hose tube.
4. If blockage is not found in tube, remove bottom plate,
belt and agitator. (See Belt Replacement, page 6)
5. Remove agitator shield and remove any loose debris
which may have accumulated.
RECOMMENDATIONS
Figure 39
0114 IH-3956