SECTION 21—M71 BATTERIES

Using the Proper Batteries

NOTE: For this procedure, refer to FIGURE 21.1 on page 160.
1. Place battery on ground/flat surface.
2. Visually draw a horizontal and vertical centerline through the middle of battery
(FIGURE 21.1).
3. Position the battery so that the terminals are above the horizontal centerline.
4. Visually inspect the battery to ensure the correct position of the POSITIVE and
NEGATIVE terminals (FIGURE 21.1):
Batteries with terminal configuration as shown below MUST be used. Batteries
that have the reverse terminal configuration MUST NOT be used - otherwise
injury and damage may occur.
Terminals MUST have a cross hole in them as shown below
Use This Configuration
U1 Battery

Removing/Installing Batteries from/into Battery Tray

Always use the battery handle or lifting strap when lifting the battery. It is the most
convenient method and assures that the battery acid will not spill. It also helps to
prolong the life of the battery.
DO NOT tip the batteries. Keep the batteries in an upright position.
NOTE: For this procedure, refer to FIGURE 21.2 on page 162.
Formula
PTO Plus Powered Seating
WARNING
NEGATIVE (-)
Battery Terminal
NEGATIVE (-)
Battery Terminal
Cross Holes
POSITIVE (+)
Battery Terminal
FIGURE 21.1 Using the Proper Batteries
WARNING
160
Do Not Use
POSITIVE (+)
Battery Terminal
U1 Battery
Part No 1125031