IBM 5110 Series Maintenance Analysis Procedures page 171

Hide thumbs Also See for 5110 Series:
Table of Contents

Advertisement

(~"-'~I
...
(':
(' ' ' 1 1,
_ /
c
c'
c
KEYBOARD MAP 0600
PAGE 1 OF 7
ENTRY POINTS
FROM
ENTER THIS MAP
MAP
ENTRY PAGE
STEP
NUMBER
POINT NUMBER NUMBER
0200
A
0300
A
0845
A
0900
A
001
(Entry Point A)
Can you make the machine fail?
Y N
002
(Entry Point B)
001
001
001
001
Go to the FREELANCE TROUBLESHOOTING
GUIDE in the Diagnostic Aids section of the
5110 MIM.
003
Make the machine fail.
Is the PROCESS CHECK light on?
Y N
004
-Calibrate the multimeter (see MIM 270).
-For the probe points see MIM 206 and 255.
- Measure +8.5 Vdc and +5.0 Vdc at the
keyboard PC board with referance to N2D08
(gnd) on the A 1 board.
Are both voltages in tolerance (+7.8 Vdc to
+9.3 Vdc and +4.6 Vdc to +5.5 Vdc)?
Y N
©
Copyright IBM Corp. 1979
722
EXIT POINTS
EXIT THIS MAP
TO
PAGE
NUMBER
7
2
STEP
NUMBER
077
006
MAP
NUMBER
0420
0700
01JAN79
MAP 0600-1
ENTRY
POINT
A
A
EC 836600
PEC 835541
ABC
MAP 0600-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

5110 system

Table of Contents