Map Organization 0100-2 - IBM 5110 Series Maintenance Analysis Procedures

Hide thumbs Also See for 5110 Series:
Table of Contents

Advertisement

MAP ORGANIZATION
START
Start MAP 200
Record the Error Code Displayed
Indicator Lights-Use MAP 200
Other Reported Fail u res
-------f..----------------------1~O-~L-
__________________________
~
NoSymptoms---------------+---------------,
Begin each call with Start MAP 200. This MAP ensures
that the system is operating sufficiently to use other
MAPs or MDls.
Start MAP 200 asks you to record the status bytes, error
logs, and history logs because this information is lost
on power down or RESTART. The Start MAP either fixes
or directs you to a MAP that tells you how to fix any of
the following problems:
I ndi cator lights
Bring up failures
Process checks
Display failures
For other failures, the Start MAP directs you to the correct
MAP through an error code. If you are certain the failure
is not covered in the Start MAP, you can go directly to the
other MAPs indicated by the
®
in the chart.
All MDls have a MAP as an entry. For example, MAP
810-5103 is an entry for MOl 800 through 805. These
MAPs provide the setup instructions for running the MDls.
The MDls are a combination of MAPs and diagnostics.
The MD Is call in and run the appropriate diagnostics
and answer most of the MAP questions automatically.
The procedures for diagnosing intermittent failures
contain a more detailed description of what part of the
system each MOl checks.