Flue Gas Test; Emissions Test Button; Measuring Co Content Of The Flue Gas - Bosch Greenstar FS Series Installation And Maintenance Instructions For Contractors

Residential gas condensing boiler
Table of Contents

Advertisement

Do not operate the appliance if the measured value is below or above
these values. Determine the cause and eliminate the fault. If this is not
possible, block the appliance on the gas side and notify the gas supplier.
▶ Press the emissions test button C until the light goes out. The display
returns to the supply temperature.
▶ Switch the appliance OFF, turn off the gas cock, remove the pressure
gauge and tighten the screw in the test port for gas inlet pressure.
▶ Reinstall the cover.
Greenstar FS/Combi FS – 6 720 810 590 (2020/04)
13

Flue gas test

13.1

Emissions test button

The following appliance outputs can be selected by pressing the
emissions test button
until it lights up:
3
4
2
5
1
6
max
Fig. 80 Press the emissions test button
= Maximum set output in heating mode ( Maximum heating
output, page 57)
= maximum nominal output
= Minimum nominal output
You have 15 minutes to complete the tests. After that, the appliance
returns to default mode.
13.2

Measuring CO content of the flue gas

Use a multiport flue gas probe for the measurements.
▶ Open one of the flue gas test ports ( Fig. 75).
▶ Insert the flue gas probe approx. 2¾ inches (70 mm) into the test
port and seal around it.
▶ Press the emissions test button to select
output.
▶ Measure the CO levels.
DANGER:
Risk of flue gas poisoning.
The CO level in the flue gas must be below 200 ppm (air free).
1)
▶ If 9.4 Vol.%
CO
and a CO level under 200 ppm (af) can not be
2
achieved due to the gas supplied, use a lower CO
emissions under 200 ppm (af) instead.
▶ Repeatedly press the emissions test button C until the light goes out.
The display returns to the supply temperature.
▶ Remove flue gas probe and close the flue gas test port properly.
1) 9.4 Vol.% with NG and 11.0 Vol.% with LPG (propane)
Flue gas test
reset
eco
3
4
e
2
6
1
min
max
6 720 641 933-51.1O
= maximum nominal
level with CO
2
65