KBR...3A appliances with DHW tank: Thermal disinfection
▶ Turn the boiler high limit dial
.
3
5
2
1
6
max
Fig. 63 Summer mode
For further information, see the operating instructions for the heating
control included in the scope of delivery.
8.9

Setting frost protection

Frost protection of the heating system:
▶ Leave the appliance switched ON; set the boiler high limit to at least
95°F (35 °C) (position 1,  Tab. 26).
3
5
2
1
6
max
Fig. 64 Frost protection of the heating system
-or-
▶ If you want to leave the appliance switched OFF:
▶ Mix Bosch-approved anti-freeze into the heating water (Tab. 15)
and drain the DHW circuit.
For further information, see the operating instructions for the heating
control included in the scope of delivery.
Frost protection of the DHW tank:
▶ Leave the appliance switched ON; set the boiler high limit to at least
95 °F (35 °C) (position 1,  Tab. 26)
▶ Turn the DHW thermostat * counterclockwise to min
(59 °F (15 °C)).
3
4
2
5
1
6
max
Fig. 65 Frost protection for the DHW tank
8.10

Activating the key pad lock

The key pad lock affects the boiler high limit dial, the DHW thermostat,
and all buttons except the ON/OFF switch, emissions test button, and
reset button. It can be used to limit unauthorized access to the boiler.
Activating the key pad lock:
▶ Press the key pad lock button until
temperature are alternating on the display.
54
counterclockwise as far as it will go:
reset
eco
3
4
e
2
6
1
min
max
reset
eco
3
4
e
2
6
1
min
max
6 720 641 933-68.1O
reset
eco
3
e
2
1
6
min
max
6 720 641 933-69.1O
and the heating supply
3
4
2
5
1
6
max
Fig. 66 Key pad lock
Unlocking the key pad:
▶ Press the key pad lock button until the display shows only the supply
temperature.
9
KBR...3A appliances with DHW tank: Thermal

disinfection

Thermal disinfection covers the DHW system including the taps. For
solar DHW tanks, the solar portion of the tank is not covered.
WARNING:
Risk of scalding!
Hot water can result in severe scalding.
▶ Carry out thermal disinfection only outside the normal hours of use,
or install a tempering valve.
▶ Close all DHW taps.
▶ Advise occupants of the risk of scalding if no tempering valve is
installed.
▶ Set the time and DHW temperature accordingly on the heating
control with DHW program.
▶ Set any DHW recirculation pump to continuous operation.
▶ Turn DHW thermostat clockwise to max (approx. 158 °F (70 °C)).
3
4
2
5
1
6
max
Fig. 67 Thermal disinfection
▶ Wait until the maximum temperature has been reached.
▶ Open all DHW taps, from the nearest to the one furthest away, and
draw off hot water until it reaches a minimum of 158 ? ‹ F (70 ? ‹ C) at
all taps for at least 3 minutes.
▶ Reset the DHW thermostat, DHW recirculation pump, and heating
control to standard operation.
Thermal disinfection can also be carried out automatically and on a
regular basis; see operating instructions for the heating control included
in the scope of delivery.