Technical features

Table 1-1
Technical features
Technical feature
Insulation of the stator winding in acc.
with EN 60035 (IEC 60034-1)
Installation altitude according to
EN 60034-1 (IEC 60034-1)
Type of construction according to
EN 60034-7 (IEC 60034-7)
Degree of protection to
EN 60034-5 (IEC 60034-5)
Permissible coolant temperature
Coolant intake temperature
Temperature monitoring acc. to
EN 60034-11 (IEC 60034-11)
Paint finish
2. rating plate
Drive shaft end according to
DIN 748-3 (IEC 60072-1)
Hollow-shaft bore
Radial eccentricity, concentricity and
axial eccentricity acc. to
DIN 42955 (IEC 60072-1)
Vibration severity according to
EN 60034-14 (IEC 60034-14)
Sound pressure level according to
DIN EN ISO 1680
Built-in encoder systems for motors
without DRIVE-CLiQ interface
Built-in encoder systems for motors
with DRIVE-CLiQ interface
Terminal box arrangement (when
viewing the DE)
Terminal box connection type
Motor
Fan (1PM6 only)
Encoder system and temperature
sensor
Options
1)
S/R = signals/revolution
2)
With option L37: 72 dB(A) +3 dB(A)
1PM6/1PM4 Hollow-Shaft Motors for Main Spindle Drives
Configuration Manual, PPMS, 04/2008, 6SN1197-0AD23-0BP0
1PM6
Temperature class 155 (F) for a coolant
temperature of up to +40 °C
≤ 1000 m above sea level, otherwise
power derating
IM B5 (IM V1, IM V3)
IP55, fan IP54
-15 ... +40 °C
2 temperature sensors KTY 84 in the stator winding, 1 as reserve
Grade A is observed up to rated speed
From drive end to non-drive end (when
fan is operating on a 50 Hz supply)
70 dB(A) +3 dB(A)
2)
Incremental encoder, sin/cos 1 Vpp, 256 S/R
Incremental encoder, 19-bit (resolution 524288, internal 256 S/R), without
commutating position (Encoder IN19DQ)
For axial fan:
Top, rotatable 4 x 90°
For radial fan:
On right side, rotatable 4 x 90°
Terminals in terminal box
Terminals in terminal box
17-pin circular socket (without mating
connector or DRIVE-CLiQ)
Version
Temperature class 155 (F) for a coolant
temperature of up to +30 °C
IM B35 (IM V15, IM V36)
IP65, IP55 on shaft exit
Due to the risk of condensate formation,
a coolant intake temperature of up to
+30 °C is recommended depending on
the prevailing ambient conditions.
Anthracite, similar to RAL 7016
Enclosed separately
Plain shaft, without fitted key
∅ 11.5 mm
Tolerance R (reduced)
69 dB(A) +3 dB(A)
(IN256S/R encoder)
Top, rotatable 4 x 90°
Terminals in terminal box
---
17-pin circular socket (without mating
connector or DRIVE-CLiQ)
L37 = higher maximum speed
Description of the motor
1.3 Technical features
1PM4
2)
without C and D tracks
1)
17