11
Function of automatic wiring/piping correction

11.2 How to activate this function

1. Check that outside temperature is above 5°C.
(This function does not work when outside temperature is not above 5°C.)
2. Check that the stop valves of the liquid pipe and gas pipe are open.
3. Turn on the breaker and wait at least 2 minutes.
4. Press the check switch on the outdoor PCB board unit LED display "CE".
Free match split type air conditioner / Installation Manual
B
A
Terminal
B
block
A
Liquid/
B
Gas pipe
A
Outdoor unit
Indoor unit B
Indoor unit A