Outdoor unit installation

6.1 Outdoor unit installation instructions

Step 1: Select installation location.
The outdoor unit should be installed in the location that meets the following requirements:
• P lace the outdoor unit as close to the indoor unit as possible.
• E nsure that there is enough room for installation and maintenance.
• T he air inlet and outlet must not be obstructed or exposed to strong wind.
• E nsure the location of the unit will not be subject to snowdrifts, accumulation of leaves or other
seasonal debris. If possible, provide an awning for the unit. Ensure the awning does not obstruct
airflow.
• T he installation area must be dry and well ventilated.
• T here must be enough room to install the connecting pipes and cables and to access them for
maintenance.
Step 2: Install outdoor unit.
Fix the outdoor unit with anchor bolts (M10)
12 / 44 EN
Strong wind
Fig. 6.1
>60cm/23.6"
Fig. 6.3
Free match split type air conditioner / Installation Manual
Strong wind
Fix with bolts