The fence voltage is below 4 kV. How do I
increase the voltage?
Check the energizer.
Disconnect the fence wire
from the energizer's fence output terminal.
Measure the voltage across the energizer terminals
with a Fault Finder or Digital Voltmeter. If the
voltage is less than 6 kV, the energizer may require
servicing.
Check the energizer earthing.
Installing and testing an earth system
described in
on page 10.
Check the fence system for faults.
common source of low voltage is faults on the
fence line.
If the fence, earth and energizer are in good
condition and the voltage is still below 4 kV, talk to
your nearest reseller. Recent extensions to your
fence, a poor fence layout, or soil conditions may
be causing inadequate voltage.
How do I locate faults?
The recommended tool for locating faults is a Fault
Finder. This combined voltage and current meter
allows you to rapidly locate sources of current
leakage. Alternatively, use a Digital Voltmeter. Use
cut-out switches to turn off the power to different
sections of the farm. If the voltage on the fence

Product Specifications

Power supply
Power consumption using a power adaptor
Current consumption using a 12 V, lead-acid battery
Fast speed
Slow speed
Maximum output voltage
Maximum output energy
Stored energy
14
Use the procedure
The most
increases when a section of the farm is turned off,
then investigate that section for possible faults.
There are no lights flashing on the energizer.
Ensure the power supply is on. Check the fence
system for faults (see above). Check the energizer
(see above). If the energizer still does not operate,
it may require servicing.
Servicing
This energizer uses Double Insulation, where two
systems of insulation are provided instead of
grounding. No equipment grounding means is
provided in the supply cord of a double-insulated
energizer, nor should a means for equipment
grounding be added to the energizer. Servicing a
double-insulated energizer requires extreme care
and knowledge of the system and should only be
done by qualified service personnel. Replacement
parts for a double-insulated energizer must be
identical to the parts they replace. A double-
insulated energizer is marked with the words
DOUBLE INSULATION or DOUBLE INSULATED
and/or the symbol below.
1 J model
2 J model
12 V battery,
or approved power adaptor 100-240 V
2.0 W
3.2 W
110 mA
210 mA
60 mA
105 mA
9.8 kV
11.0 kV
1 J at 500 
2 J at 300 
1.4 J
2.7 J
3 J model
4.8 W
340 mA
165 mA
11.4 kV
3 J at 200 
4.5 J