Note:
If five Indicator light segments are illuminated, the output voltage may be more than 5 kV (5000 V).
If you see only red lights at each pulse and no green lights, your fence line is very heavily loaded, and you
will need to look for faults on the fence line. See
Battery test setting
When the energizer is connected to a battery and the Selector switch is set to Battery Test ( ) the Indicator
lights show the charge level of the battery for a period of 30 seconds.
Indicator lights
While the battery charge level is being displayed, the Indicator lights will also flicker briefly with each
energizer pulse in order to show that the energizer is still functioning. After 30 seconds, the Indicator lights
revert to displaying the energizer output voltage. When set to Battery Test, the energizer pulses at Slow
speed and delivers Full Energy at all times.
Note:
The battery test is only relevant when a lead-acid battery is used.
6
Frequently asked questions/Troubleshooting
Battery-only installation
Excellent battery charge level (90-100%):
No action required.
Very good battery charge level (70-90%):
No action required.
Average battery charge level (40-70%):
Monitor battery charge level.
Recharge the battery to avoid long-term damage to the battery.
Poor battery charge level (20-40%):
Monitor battery charge level.
Recharge the battery to avoid long-term damage to the battery.
Very poor battery charge level (0-20%):
Recharge the battery immediately.
on page 13.