INSTALLATION PROCEDURES
Figure 7: Seawater Piping Recommendations
Thru-Hull Inlet Fitting
A separate thru-hull fitting must be installed for each seawater pump. Do not attempt to draw water from the thru-hull fitting of an
engine, generator, or other device.
Install a scoop-type thru-hull fitting:
1.
Drill a properly sized hole for the thru-hull fitting as far below the water line and as close to the keel as possible.
2.
Make sure the scoop of the thru-hull fitting faces the bow.
3.
Bed the scoop with marine sealant designed for underwater use, and tighten the nut onto the thru-hull to secure it.
Seacock
The seacock must be accessible and easy to close in case of emergency or to clean the strainer.
1.
Install a full-flow seacock directly onto the thru-hull fitting.
2.
Use threaded-seal tape to seal the threads.
Seawater Piping
•
Only use reinforced marine-grade hose or other suitable piping (PVC, CPVC, cupronickel, or stainless steel).
•
Double clamp all hose connections.
•
Use only plastic, bronze, or stainless steel fittings (do not use brass).
•
Avoid loops or dips in all hose runs.
•
Make sure enough hose is used to allow for future removal of components.
10
Eskimo Ice Installation & Operation Manual
L-3040 ENGLISH