Download Print this page

Alpha ESS SMILE-BAT-10.3P Quick Installation Manual page 6

Integrated ems
Hide thumbs Also See for SMILE-BAT-10.3P:

Advertisement

Close Maintenance Window
Step10
Close the two maintenance panels and the battery front panel.
( Tool: T20  screwdriver, torque: 2.5Nm)
Turn ON the battery circuit breaker.
Maintenance Panel for Battery Circuit Breaker
Configuration of DIP Switch
1. If there is only one battery, DIP switch of battery should be set as
below:
Battery
DIP 1
DIP 2
Position
One BAT
OFF
OFF
Communication Connection Window
DIP
DIP 3
DIP 4
Switch
OFF
OFF
Add Extra Batteries
Step11
Install another battery, please repeat Steps 1 ~ 10.
Please install extra batteries only by the side if more are to be added.
You can add up to 6 batteries in a system.
The complete system needs EMS, the first battery should be the one
with EMS
2. If there are two or more than two batteries, DIP switch of batteries
should be set as below:
Battery
DIP 1
DIP 2
Position
Other
OFF
OFF
BAT
Farthest
OFF
ON
BAT
......
DIP
DIP 3
DIP 4
Switch
OFF
OFF
OFF
OFF

Advertisement