Behaviour During A Power Failure / Behaviour After The Power Returns (Without Emergency Battery); Inspection And Maintenance; Replacement Bulb; Optional Accessories - 4Ddoors GA103 Instructions For Fitting, Operating And Maintenance

Hide thumbs Also See for GA103:
Table of Contents

Advertisement

ENGLISH
11.3.2 channel 2 / partial opening function
The door behaves as follows if an external button (at terminal
20 / 23) or a taught-in hand transmitter button for the partial
opening function (channel 2) is pushed.
From the Close end-of-travel position:
1st impulse:
→ The door moves in the partial opening
direction.
2nd impulse: → The door stops.
3rd impulse:
→ The door moves in the partial opening
direction.
etc.
From the Open end-of-travel position:
1. Impuls:
→ The door moves in the partial opening
direction.
2nd impulse: → The door stops.
3rd impulse:
→ The door moves in the partial opening
direction.
etc.
From the partial opening position:
Impulse at
→ The door moves in the Open direction.
terminal 20/21
Impulse at
→ The door moves in the Close direction.
terminal 20/23
The operator light will light up during a door run and go out after
approx. 2 minutes.
11.4 behaviour during a power failure / behaviour
after the power returns (without emergency
battery)
To be able to open or close the garage door by hand during a
power failure, it must be disengaged from the slide carriage while
the door is closed, see „Manual operation" on page 6.
After the power returns, the slide carriage for automatic
operation must be re-engaged, see „Automated operation"
on page 6.
Due to safety reasons, if the power fails during operation, the fi rst
impulse command will always open the door.
12

inspection And mAintenAnce

The garage door operator is maintenance-free.
In the interest of your own safety, we recommend having the
door system inspected and maintained by a qualifi ed person
in accordance with the manufacturer's specifi cations.
wArning!
danger of injury due to unexpected door travel!
Unexpected door travel may occur during inspection and
maintenance work if the door system is inadvertently
actuated by other persons.
Disconnect the mains plug and the plug of the emergency
battery whenever performing work on the door system.
Safeguard the door system against being switched on again
without authorisation.
Inspection and repairs may only be carried out by a qualifi ed
person. Contact your supplier for this purpose.
A visual inspection may be carried out by the operator.
EBA GA103_4ddoors_GBR, Rev. 1.0, 25.04.2014.indb 18
18
Check all safety and protective functions monthly.
Check safety devices without self-testing every six months.
Any malfunctions and / or defects must be remedied
immediately.

12.1 replacement bulb

Only use a 24 V / 10 W B(a) 15 s bulb.
Exchange the light bulb only if the operator is voltage-free.
13

optionAl Accessories

Optional accessories are not included in the scope of delivery.
Loading of the operator by all electrical accessories:
max. 100 mA.
The following accessories can be connected to the operator:
• One-way photocell, self-testing dynamic photocell
• External radio receiver
• External impulse buttons (e.g. key switches)
• Emergency battery for emergency power supply
• Wicket door contact
• Warning light (in combination with the relay PR 1)
14

dismAntling And disposAl

When dismantling the door, observe the applicable regulations
governing work safety.
Have a specialist dismantle the garage door operator in the
reverse order of these instructions and dispose of it properly.