  • Page 1 Garage Door operator GA201 SOLAR www.4ddoors.com.au...
  • Page 2 ENGLISH Dear Customer, Before installing the operator, it is therefore necessary to check the door and make sure that it can Thank you for choosing this quality product from our company. also be easily moved by hand. Please keep these instructions safe for later reference! To do this, raise the door approx.
  • Page 3 ENGLISH The clearance between the highest point of the door and Regarding necessary repairs contact your supplier. We the ceiling (also when the door is opening) must be at shall accept no responsibility for improper and least 30 mm (see fig. 1.1a / 1.1b).
  • Page 4 13 mm 10 mm Ø 10 mm 4 mm Ø 5 mm 10.2004 V1.0 / 201_AKKU...
  • Page 5 1.2a 1.3a 1.2 a 1.3 a 1.2.2 / 2.1 1.1a 1.2 a 1.3a 10.2004 V1.0 / 201_AKKU...
  • Page 6 1.4b 1.5b 1.6b 1.2b 1.4 b 1.5 b 1.6 b 1.3b 1.2b 1.1 b 1.2b 1.2.2 1.3 b 10.2004 V1.0 / 201_AKKU...
  • Page 7 1.4 b 1.5 b 1.6 b 10.2004 V1.0 / 201_AKKU...
  • Page 8 3.1a 1 / 2 1 / 2 N 80 3.2 a 1 / 2 1 / 2 N 80 3.3 a 1 / 2 1 / 2 DF 98 3.4 a 1 / 2 1 / 2 F 80 10.2004 V1.0 / 201_AKKU...
  • Page 9 2.5 / 2.6 LTE / LPU/LTH 40 3.1b ≥ 113 LTE / LPU/LTH 40 3.2b > 55 10.2004 V1.0 / 201_AKKU...
  • Page 10 4.2/4.3 10.2004 V1.0 / 201_AKKU...
  • Page 11 5.2-5.4 10.2004 V1.0 / 201_AKKU...
  • Page 12 6.1a - 6.2a 6.1a N 80 6.2 a DF 98 10.2004 V1.0 / 201_AKKU...
  • Page 13 6.1b- 6.2b 6.1b 6.2 b 10.2004 V1.0 / 201_AKKU...
  • Page 14 10.2004 V1.0 / 201_AKKU...
  • Page 15 1.2.2-4) 10.2 3.3.2-3) / 3.4 10.1 10.2 / 10-14 3.3.2-1) / 3.6.2 10.2004 V1.0 / 201_AKKU...
  • Page 16 3.5.2 21 20 12 13 3.5.3 21 20 12 13 1 2 3 4 5 3.3.2/3.5.4 Programmierkurzanleitung Programming quick reference guide Lernbetrieb: teach-in mode: 24V/10 W Press and black button and hold it down until Schwarze Taste drücken und gedrückt halten, 24V/10W the light flashes 2X. Then release the button.
  • Page 17 3.3.1 3.3.2 6 sec. 1 sec. 3.3.3-4) 10.2004 V1.0 / 201_AKKU...
  • Page 18 2 Montageanleitung Installation instructions Hinweis Note 2.1 Benötigter Freiraum für die Montage des Antriebes Wenn sich das Tor per Hand nicht einfach in die If the door cannot be easily pushed to the desired "Door 2.1 Space required to install the drive Antriebs-Montage muss Freiraum...
  • Page 19 Diese verkürzt sich bei höheren oder niedrigen Einsatz an einem anderen Tor oder wenn sich das Tor This becomes shorts with higher or lower positions and if the running characteristics of the door substantially change (e.g. if the limit stop is subsequently moved or Temperaturen und mit dem Altern des Akku-Packs.
  • Page 20 the door stops immediately. The next time the button We only recommend reducing the setting for a door das Tor sofort, beim nächsten Betätigen der Taste Ein Verkleinern ist nur dann sinnvoll, wenn es sich um is operated, the door moves in the opposite direction. that moves easily, if you would like a higher level of fährt das Tor in die Gegenrichtung.
  • Page 21 Hinweis - Electrical connections may only be performed by - Elektroanschlüsse dürfen nur von einer Elektro- Note Durch das Öffnen des Kontaktes werden eventuelle a skilled electrician! Fachkraft durchgeführt werden! Breaking the contact stops any door movements which Torfahrten sofort angehalten und dauerhaft unter- - The - Die bauseitige Elektroinstallation muss den on-site...
  • Page 22 3.6.1 Normal-Betrieb Remedy: Perform teach-in process Behebung: Einlernvorgang durchführen 3.6.1 Normal operation (siehe Kapitel 3.3.2). Der Garagentorantrieb arbeitet im Normal-Betrieb The garage door opener operates in normal mode (see Chapter 3.3.2). exclusively with pulse sequence control. It does not ausschließlich mit der Impulsfolgesteuerung, wobei es 3 flashes every 4 seconds unerheblich matter whether an external button, a programmed...
  • Page 23 ENGLISH Measures following error message Causes of possible error messages: Note: If a STOP or emergency-OFF circuit is not The learned distance is too short, < 60 cm. connected to terminals 20 and 71, check During an automatic travel cycle when running whether the DIP switch 2 (SCH1) is set at through the learning procedure, the operating or "ON"...
  • Page 24 ENGLISH Performance 6.5.3 Operator fails to work with externally connected During the warranty period we undertake to rectify any buttons: and all faults on the product which can be proved to Check buttons, leads and connecting terminals. be attributed to a material or manufacturing defect. We pledge to provide free of charge and at our discretion, parts and service labour to repair or replace any part of the product that fails due to a manufacturing defect,...
  • Page 25 ENGLISH Quick release: In the event of a power failure, actuated from the inside via a pull cord Remote control: 4-button hand transmitter RCBE 868/4 (868.360 MHz) and separate receiver. Universal fitting: for up-and-over and sectional doors Door speed: approx. 135 mm/s (depending on size and weight of door) Airborne noise emission Garage...