Page 3
Start-up Close the isolating valve on the discharge side of the pump and Remove the priming plug from the pump head and slowly fill the open the isolating valve on the suction side. pump with liquid. Replace the priming plug and tighten securely. Remove a coupling guard.
Page 4
Запуск Перекройте запорный клапан со стороны выпуска насоса и Выньте пробку из заливочной горловины и медленно откройте запорный клапан со стороны всасывания. заполните насос жидкостью. Установите пробку заливочной горловины на свое место и прочно затяните. Снимите соединительную защитную пластинку. Запустите насос и дайте ему поработать в течение короткого периода...
Page 5
CRNE-HS Installation and operating instructions Montage- und Betriebsanleitung Monterings- og driftsinstruktion Руководство по монтажу и эксплуатации...
Page 6
Maintenance - 8 Megging - 8 4. Applications Coupling adjustment - 8 The Grundfos CRNE-HS pump is designed to handle pressures Technical data - 9 up to 48 bar. The pump is fitted with a frequency-controlled motor 14.1 Supply voltage - 9 with a speed of up to 5440 min depending on motor size.
5.2 Inlet pressure 5.2.1 Pressure test The pump may be tested at a static pressure of 55 bar. Minimum inlet pressure During the test, the pump shaft must be locked to Note prevent axial movement. To lock the pump shaft, proceed as follows: 1.
8. Start-up means of the Grundfos wireless remote control R100. All other settings are made by means of the R100. Do not start the pump until it has been filled with Important parameters such as actual value of control liquid and vented.
Page 9
This product or parts of it must be disposed of in an environmentally sound way: 1. Use the public or private waste collection service. 2. If this is not possible, contact the nearest Grundfos company or service workshop. Subject to alterations.
1. Installation in the USA and Canada In order to maintain the UL/cUL approval, these additional instal- lation procedures must be followed. The UL approval is according to UL508C. 1.1 Electrical installation 1.1.1 Conductors Use 140/167 °F (60/75 °C) copper conductors only. 1.1.2 Torques Power terminal, M4: 2.35 Nm.
Page 11
Fig. A Fig. B NPSH (°C) C R N E 1 - 2 3 H S [ k P a ] [ m ] 1 0 0 0 . 0 0 . 5 1 . 0 1 . 5 2 . 0 2 .
Page 12
Fig. C Dimensional sketch Dimensions and weights Net weight Dimensions [mm] [kg] Motor Pump type [kW] PJE/CX PJE/CX B1 + B2 B1 + B2 CRNE 1-23 HS 1052 1087 CRNE 1-23 HS 1071 1106 CRNE 1-23 HS 1071 1106 CRNE 3-23 HS 1052 1087 CRNE 3-23 HS...
Page 13
CRNE 1 and 3 HS Fig. D M6 - 13 Nm M8 - 31 Nm M10 - 62 Nm M5 - 2.5 Nm...
Page 15
Tel.: +43-6246-883-0 Telefax: +49-(0) 211 929 69-3799 Veluwezoom 35 Turkey Telefax: +43-6246-883-30 e-mail: infoservice@grundfos.de 1326 AE Almere GRUNDFOS POMPA San. ve Tic. Ltd. Sti. Service in Deutschland: Postbus 22015 Gebze Organize Sanayi Bölgesi Belgium e-mail: kundendienst@grundfos.de 1302 CA ALMERE N.V. GRUNDFOS Bellux S.A.
Page 16
Thinking ahead makes it possible Innovation is the essence 96477321 0110 The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks Repl. 96477321 0205 owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. www.grundfos.com...