5.3 Hardware Setup Instructions

Step 1
Insert CBL31 USB connector (USB3.0 micro b)
into the USB3.0 receptacle on the camera.
Tighten BOTH thumb screws to the secure
CBL31 to the camera.
Note: Failure to connect CBL31 to the camera
with BOTH thumb screws can result in damage
to the USB3.0 receptacle on the camera.
Step 2
Insert the stereo jack portion of CLB31 into the
receptacle on the camera.
Step 3
Insert the USB Type A end of CBL31 into a
USB3.0 port on the host computer.
Note: ONLY two cameras per USB controller or
USB hub are supported.
Step 4
Insert the stereo jack portion of CBL31 into any
of the "Sync Out" ports of the MyoSync station.

5.4 Select and attach your lens (300C only)

Select a lens based upon the field of view that is needed for your specific use-case. Refer to the Section
11.3 of the hardware manual for details on selecting the appropriate lens. The following fixed-focal
length lenses are available for use with this camera:
a. Navitar 3.5 mm
b. Navitar 4.5 mm
c.
Navitar 6 mm
d. Navitar 12 mm
(Rev B)