EU, 2006/42/EC, 2014/30/EU and 2011/65/EU and conforms with the following standards or normative documents: EN 61010-1, EN 61010-2-051, EN 61326-1, EN 60529 and EN ISO 12100� A copy of the complete EU Declaration of conformity can be requested at sales@ika�com� Explication of warning symbols...
Page 7
/// Device setup Danger! › Please pay attention to the dangerous parts of the equipment in Fig� 1� Danger! › Do not use the device in explosive atmospheres, it is not EX-protected� › With substances capable of forming an explosive mixture, appropriate safety measures must be applied, e�g�...
Page 8
› Process pathogenic materials only in closed vessels under a suitable fume hood� /// Accessories › Safe operation is guaranteed only with the use of original IKA accessories� › Always disconnect the plug before attaching accessories� › Accessories must be securely attached to the device and cannot come off by themselves� The centre of gravity of the assembly must lie within the surface on which it is set up�...
Intended use /// Use The MATRIX ORBITAL DELTA shaker is used to mix liquids� These can be shaken in sample vessels or sample plates, perhaps also using different inserts� /// Range of use Indoor environments similar to that of a laboratory in research, education, commerce or industry�...
/// Scope of delivery › Please unpack the device carefully; › Any damage should be notified immediately to the shipping agent (post office, railway net- work or logistics company)� IKA Matrix Orbital DELTA Warranty card Mains cable USB cable User guide /// Device Setup Fig.
Assembly /// Connection to the power supply /// Mount the inserts/sample plates › Deepwell plates (DWP) › Microtiter plates (MTP) /// Mount the sample vessels...
Operator panel and display /// Explanation of the control elements Pos. Designation Function Graph key Speed/time diagram Timer key Editing/activating the timer Program key Program management › press 1x: Back to main menü Menu key › press 2x: Back to working display Back key Returns to previous menu level ›...
Page 13
ThermoCover is connected to the device detecting Fast Temperatur The set temperature control rate is displayed on the main screen control rate Moderate Slow Power failure Showed a previous power supply interruption Device variant Used inserts/sample plates/sample vessels IKA MATRIX 1.5 ml...
Menu navigation and structure /// Menu navigation › Press “Menu” button (D)� › Select a menu item by pressing the “(+)” button (I) or the “(-)” button (H)� › Confirm the menu item by pressing the “ ” button (G)� ›...
Page 16
/// Menu details Mixing Intermittent mode: In the menu you can select/carry out various settings for the direction of rotation and the mixing process: 1� Tick (): Intermittent mode option activated 2� CW time: set 3� Stop time: set 4� CCW time: set Symbolic Graph representation...
Page 17
Modes After switching on/mains power interruption, the functions do not restart automatically� After switching on/mains power interruption, the functions restart automatically, de- pending on previous settings� Setpoints (set in A or B) cannot be changed� After switching on/mains power interrup- tion, the functions restart automatically, depending on previous settings�...
Page 18
Time hh:mm:ss Mixing CW/CCW/CW & CCW direction Edit: To edit/change the program parameters� Insert: Inserts a new program segment after the selected segment� Delete: To delete the program segment Save: Save the changes Delete: Delete all program parameters of the selected program using the navigation buttons +/- and button (G), “Delete”...
After the start screen, the information start screen for the Firmware Update Tool appears� You can use the tool to update the software of your IKA device to the latest version� Firmware updates contain new functions or optimisations of previous functions� You can download the Firmware Update Tool at www�ika�de/fut�...
First, download the latest driver for IKA devices with USB port from: https://www.ika.com/ika/lws/download/usb-driver.zip Install the driver by running the setup file� Then connect the IKA device through the USB data cable to the PC� The data communication is via a virtual COM port�...
Page 22
The NAMUR commands and the additional specific IKA commands commissioning serve only as low level commands for communication between the device and the PC� With a suitable ter- minal or communications program these commands can be transmitted directly to the device�...
› Do not allow moisture to get into the device when cleaning� › Before using another than the recommended method for cleaning or decontamination, the user must ascertain with IKA that this method does not destroy the device� /// Spare parts order When ordering spare parts, please give: ›...
› Send the device for repair, including a short description of the fault� Warranty In accordance with IKA warranty conditions, the warranty period is 24 months� For claims under the warranty please contact your local dealer� You may also send the machine direct to our factory, enclosing the delivery invoice and giving reasons for the claim�...
Counter 1 s … 99 h 59 m 59 s (∞) Programming Interval and program mode Remote Labworld Soft Software Update IKA Firmware Update Tool Interfaces RS 232 9-pol Sub-D (back side) Type B (front side) Subject to technical changes!
Page 26
Phone: +81 6 6730 6781 Phone: +91 80 26253 900 Phone: +44 1865 986 162 eMail: info@ika�in eMail: info_japan@ika�ne�jp eMail: sales�england@ika�com Discover and order the fascinating products of IKA online: www.ika.com IKAworldwide IKAworldwide /// #lookattheblue @IKAworldwide Technical specifications may be changed without prior notice�...