Installation
a Top box
b Appliance
c Housing unit
d Wall
x: The appliance depth is increased by
approx. 35 mm for appliances with
wall spacers fitted.
The appliance can be built into a run of
kitchen units and installed directly next
to a kitchen furniture unit. The front of
the appliance then protrudes 65 mm
(approx. 100 mm if wall spacers are
fitted) from the front of the adjacent
furniture unit.
50
This enables the doors to be opened
and shut without being obstructed. To
match the height of the kitchen units in
the run, the appliance can be fitted with
a suitable top box .
When installed next to a wall  a
distance of at least 45 mm must be
maintained on the hinge side between
the wall  and the appliance .
The larger the ventilation gaps, the
more economically the compressor
will work.
– A ventilation gap of at least 50 mm
depth must be provided at the back
of the appliance behind the whole
width of the top box for air to
circulate.
– The ventilation gap under the ceiling
must be at least 300 cm
that the warm air can escape
unhindered.