7.2 TO RESET FACTORY SETTINGS

ATTENTION
Loads all default values and deletes all previous values entered.
The factory values can be loaded by pressing a sequence of keys.
Key sequence to reset setting, press DOWN, ESC, ARROW DOWN, ESC, ARROW DOWN, ESC, press for 10 seconds.
Press SET to confirm reset.

7.3 SOFTWARE VERSION

Key sequence to see the software version, ARROW UP for 5 seconds.
CHaPter 8

taBLeS anD DeSiGnS

8.1 DATA PLATE

1) Type of motor pump
2) Maximum flow rate l/min
3) Nominal power (P2)
4) Maximum temperature of liquid
5) Nominal current
6) Maximum head in metres
7) Insulation class and level of
protection
8) Absorbed current
9) Date and year of production
10) Frequency
11) Software version
12) Power voltage
13) Number of phases
14) Absorbed power (P1)