General System Reset; Resetting And Factory - Pentair NOCCHI CPS 10 Manual

Table of Contents

Advertisement

GB
MESS. DISPLAY
DESCRIPTION
over voltage error
e08
temporary.
over voltage error
e09
definitive.
absence of network power
e10
(in memory)
e11
Power error.
e12
Memory error.
e13
Configuration error.
e99
Undefined error.
485e
Communication error.
CHaPter 7
reSettinG anD FaCtorY SettinGS

7.1 GENERAL SYSTEM RESET

ATTENTION
Press only as a last resort to restart the system.
Triggers a general module reset and reloads set values saved in eeprom. Press as a last resort only in order to restart the module.
If, for whatever reason, the module becomes blocked, wait approximately 10 seconds for the module itself to automatically launch a
general reset. If this does not reset the system, use this key and contact a customer care centre.
Reset key sequence, press SET for 20 seconds.
36
this error condition occurs when the voltage exceeds by
10% the nominal voltage (230V).
this alarm condition closes the J3 contact on the power
board for possible external signals (alarm light, siren, etc.)
a definitive over voltage error occurs after a temporary over
voltage error is repeated 5 times.
this condition occurs following a network absence.
this condition indicates a motor power absorption error in
terms of its running status.
this error occurs when eeprom is unable to load the
parameters which have been entered.
this error occurs when the control board cannot correctly
communicate with the power part. this alarm condition
closes the J3 contact on the power board for possible
external signals (alarm light, siren, etc.).
this error occurs when an unforeseen error takes place.
this signal refers to pump units and is indicated when the
devices are not communicating correctly.
ACTION
in this case, the module will attempt to restart normal functioning
after 1 minute and will repeat the procedure up to five times. Press
the button Start/StoP or cut the power off and wait until the Line
Led switches off and after which restart the system.
if the error occurs again, contact customer care.
Press the Start/StoP button or cut off power and wait until the red
Led Line goes off, then power again to reset the system.
if the error occurs again, contact your nearest customer care centre.
Wait for a few minutes. if the signal remains, press the button
Start/StoP or cut the power off and wait until the Line Led
switches off and after which restart the system.
Press the button Start/StoP or cut the power off and wait until the
Line Led switches off and after which restart the system.
if the error occurs again, contact your nearest assistance centre.
Wait for a few minutes. if the signal remains, contact your nearest
customer care centre.
Press the button Start/StoP or cut the power off and wait until the
Line Led switches off and after which restart the system.
Check the communication cable. if the error occurs again, contact
your nearest customer care centre.